High granularity resistive micromegas for future detectors

被引:0
|
作者
Biglietti, M. [1 ]
Alviggi, M. [2 ,3 ]
Camerlingo, M. T. [2 ]
Della Pietra, M. [2 ,3 ]
Di Nardo, R. [1 ,4 ]
Iengo, P. [2 ]
Iodice, M. [1 ]
Petrucci, F. [1 ,4 ]
Sekhniaidze, G. [2 ]
Sessa, M. [5 ]
机构
[1] INFN Roma Tre, Rome, Italy
[2] INFN Napoli, Naples, Italy
[3] Univ Naples Federico II, Naples, Italy
[4] Univ Roma Tre, Rome, Italy
[5] INFN Tor Vergata, Rome, Italy
关键词
Gaseous detector; MPGD; Resistive MPGD; Micromegas;
D O I
10.1016/j.nima.2024.169989
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The resistive Micromegas technology can stably operate up to O (10 MHz/cm2) particle rate thanks to novel resistive spark-protection structures suitable for readout pads of a few mm2 area. These structures are made by Diamond-Like-Carbon (DLC) in a double-layer configuration inmost of the investigated detectors with active surfaces of about 25 cm2 and in the new one with an active area of about 400 cm2. The performance in terms of gain, rate capability, robustness, dependence on the irradiated area, and space-time dedicated studies will be presented. With the proven high performance of the medium size detector and the already-started construction of a high granularity resistive Micromegas with an even larger area, our R&D is reaching the goal of establishing the technology for future large-scale and high-rate employment in Particle Physics and other fields.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] High granularity resistive Micromegas for tracking detectors in future experiments
    Camerlingo, M. T.
    Alviggi, M.
    Biglietti, M.
    Della Pietra, M.
    Di Nardo, R.
    Iengo, P.
    Iodice, M.
    Petrucci, F.
    Sekhniaidze, G.
    Sessa, M.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (05):
  • [2] High granularity resistive Micromegas for high particle rates environment
    Della Pietra, M.
    Alviggi, M.
    Camerlingo, M. T.
    Di Donato, C.
    Di Nardo, R.
    Franchellucci, S.
    Iengo, P.
    Iodice, M.
    Petrucci, F.
    Sekhniaidze, G.
    Sessa, M.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (08):
  • [3] Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam
    Banerjee, D.
    Burtsev, V.
    Chumakov, A.
    Cooke, D.
    Depero, E.
    Dermenev, A. V.
    Donskov, S. V.
    Dubinin, F.
    Dusaev, R. R.
    Emmenegger, S.
    Fabich, A.
    Frolov, V. N.
    Gardikiotis, A.
    Gninenko, S. N.
    Hoesgen, M.
    Karneyeu, A. E.
    Ketzer, B.
    Kirsanov, M. M.
    Konorov, I. V.
    Kramarenko, V. A.
    Kuleshov, S. V.
    Levchenko, E.
    Lyubovitskij, V. E.
    Lysan, V.
    Mamon, S.
    Matveev, V. A.
    Mikhailov, Yu. V.
    Myalkovskiy, V. V.
    Peshekhonov, V. D.
    Peshekhonov, D. V.
    Polyakov, V. A.
    Radics, B.
    Rubbia, A.
    Samoylenko, V. D.
    Tikhomirov, V. O.
    Tlisov, D. A.
    Toropin, A. N.
    Vasilishin, B.
    Arenas, G. Vasquez
    Ulloa, P.
    Crivelli, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 881 : 72 - 81
  • [4] Development of Micromegas detectors with resistive anode pads
    Chefdeville, M.
    de Oliveira, R.
    Drancourt, C.
    Geffroy, N.
    Geralis, T.
    Gkountoumis, P.
    Kalamaris, A.
    Karyotakis, Y.
    Nikas, D.
    Peltier, F.
    Pizzirusso, O.
    Psallidas, A.
    Teixeira, A.
    Titov, M.
    Vouters, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021, 1003
  • [5] Development of Micromegas detectors with resistive anode pads
    Chefdeville, M.
    de Oliveira, R.
    Drancourt, C.
    Geffroy, N.
    Geralis, T.
    Gkountoumis, P.
    Kalamaris, A.
    Karyotakis, Y.
    Nikas, D.
    Peltier, F.
    Pizzirusso, O.
    Psallidas, A.
    Teixeira, A.
    Titov, M.
    Vouters, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1003
  • [6] Resistive fine granularity Micromegas: characterization and performance for different spark protection resistive schemes
    Alviggi, M.
    Biglietti, M.
    Camerlingo, M. T.
    Della Pietra, M.
    Di Donato, C.
    Di Nardo, R.
    Franchellucci, S.
    Iengo, P.
    Iodice, M.
    Petrucci, F.
    Sekhniaidze, G.
    Sessa, M.
    JOURNAL OF INSTRUMENTATION, 2025, 20 (01):
  • [7] High granularity small-pad resistive micromegas for rates above MHz/cm2
    Alviggi, M.
    Camerlingo, M. T.
    D'Amico, V.
    Della Pietra, M.
    Di Donato, C.
    Di Nardo, R.
    Gimmillaro, C.
    Iengo, P.
    Iodice, M.
    Petrucci, F.
    Sekhniaidze, G.
    Sessa, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [8] Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors
    Loesel, Philipp
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 551 - 553
  • [9] Aging test of resistive Micromegas detectors operated with and without hydrocarbons
    Iengo, Paolo
    Sekhniaidze, Givi
    JOURNAL OF INSTRUMENTATION, 2023, 18 (06):
  • [10] A novel resistive anode using a germanium film for Micromegas detectors
    Feng, Jianxin
    Zhang, Zhiyong
    Liu, Jianbei
    Shao, Ming
    Zhou, Yi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1031