Experimental study on extinguishing pool fire sheltered by barrier with water mist

被引:0
|
作者
Jianghong, Liu [1 ,2 ]
Yudong, Fang [1 ]
Guangxuan, Liao [1 ]
Lin, Lin [1 ]
机构
[1] University of Science and Technology of China
[2] State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui, 230026, China
来源
Journal of Applied Fire Science | 2003年 / 12卷 / 03期
关键词
Cameras - Charge coupled devices - Fog - Nozzles - Thermal effects - Thermocouples;
D O I
10.2190/1YDK-XEBY-8EJ4-Q5CQ
中图分类号
学科分类号
摘要
In order to systematically study the interaction of water mist with flame sheltered by barrier, a series of experiments were conducted in a 8m × 10m × 5m full scale confined space with high pressure water mist system. Before and after the application of water mist, some K-type thermocouples along the liquid pool fire up-surface centerline were used to measure flame temperature and a CCD camera was used to record the extinguishment events onto VHS tapes for subsequent frame-by-frame analysis, respectively. The experimental results show that when the liquid pool fire is thoroughly sheltered by barrier, common water mist cannot extinguish the fire, but it can effectively control and suppress the fire spread and reduce the fire temperature obviously; when the liquid pool fire is sheltered partly, more water mist can reach the fire area by increasing the water mist pressure, reducing the horizontal distance and the height between the nozzle and pool fire, so the fire extinguishing time can be decreased.
引用
收藏
页码:209 / 222
相关论文
共 50 条
  • [1] Experimental Investigation of Extinguishing Fire Effectiveness on Kerosene Pool Fire With Water Mist
    Zuo Qiuling
    Wang Gongzhong
    Li Jingshan
    Fu Aiqing
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 858 - 862
  • [2] A study of the probability distribution of pool fire extinguishing times using water mist
    Liang, Tianshui
    Liu, Mengjie
    Liu, Zhonglin
    Zhong, Wei
    Xiao, Xiukun
    Lo, Siuming
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2015, 93 : 240 - 248
  • [3] Study on the effect of mist flux on water mist fire extinguishing
    Liu, Yang
    Fu, Zhixi
    Zheng, Guanghui
    Chen, Peng
    FIRE SAFETY JOURNAL, 2022, 130
  • [4] Experimental study of pool fire suppression by water mist in enclosure
    State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou 310027, China
    不详
    Zhejiang Daxue Xuebao (Gongxue Ban), 2007, 6 (1029-1035):
  • [5] Experimental study on the effectiveness of the extinction of a pool fire with water mist
    Wang, XS
    Liao, GX
    Qin, J
    Fan, WC
    JOURNAL OF FIRE SCIENCES, 2002, 20 (04) : 279 - 295
  • [6] Experimental study on extinguishing oil fire by water mist with polymer composite additives
    Liu, Ye-Cheng
    Jiang, Jun-Cheng
    Huang, An-Chi
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (11) : 4811 - 4822
  • [7] Experimental study on extinguishing oil fire by water mist with polymer composite additives
    Ye-Cheng Liu
    Jun-Cheng Jiang
    An-Chi Huang
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 4811 - 4822
  • [8] Preliminary study on extinguishing shielded fire with water mist
    Liu, Yangpeng
    Wang, Xishi
    Liu, Tong
    Ma, Jing
    Li, Guochun
    Zhao, Zihao
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 141 (141) : 344 - 354
  • [9] An experimental study of the effects of water mist characteristics on pool fire suppression
    Gupta, Meenakshi
    Pasi, Amit
    Ray, Anjan
    Kale, S. R.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 : 768 - 778
  • [10] Experimental and numerical study of pool fire suppression using water mist
    Jenft, A.
    Collin, A.
    Boulet, P.
    Pianet, G.
    Breton, A.
    Muller, A.
    FIRE SAFETY JOURNAL, 2014, 67 : 1 - 12