Design method for tuned liquid column dampers

被引:0
|
作者
Fu C. [1 ]
机构
[1] College of Civil engineering, North China University of Technology, Beijing
来源
Fu, Chuan | 2018年 / Chinese Vibration Engineering Society卷 / 37期
关键词
Design procedure; Optimal parameter; Optimal placement; Optimum geometry; Tuned liquid column damper;
D O I
10.13465/j.cnki.jvs.2018.01.029
中图分类号
学科分类号
摘要
The tuned liquid column damper(TLCD), is a cost-effective passive device to increase the structural damping. The design method for TLCD was evaluated. The most efficient placement for the absorber was determined in accordance with the dynamic characteristics of the structure. The optimum geometric parameters were analysed based on the equation of motion. The optimal frequency and damping with respect to a selected mode of the structure were simplifiedly achieved by comparing with the TMD tuning with the properly transformed Den Hartog's optimal parameters. Finally, the design procedure was gained. The numerical simulation of a 30-storey plane-asymmetric structure illustrates the effectiveness of TLCDs to mitigate the earthquake induced vibrations of plane-asymmetric buildings, and also the feasibility of the proposed method. © 2018, Editorial Office of Journal of Vibration and Shock. All right reserved.
引用
收藏
页码:196 / 202and222
相关论文
共 14 条
  • [1] Hochrainer M.J., Tuned liquid column damper for structural control, Acta Mechanica, 175, pp. 57-76, (2005)
  • [2] Diana G., Resta F., Sabato D., Development of a methodology for damping of tall buildings motion using TLCD devices, Wind and Structures, 17, 6, pp. 629-646, (2013)
  • [3] Huo L., Li H., Structural vibration control using semi-active variable stiffness tuned liquid column damper, Journal of Vibration and Shock, 31, 10, pp. 157-164, (2012)
  • [4] Zhong Z., Lou W., Vibration reduction of high-rise buildings with converted TLCD acted by wind load, Journal of Zhejiang University(Engineering Science), 47, 6, pp. 1081-1087, (2013)
  • [5] Li H., Dong S., Li H., Optimum spatial placement of dampers in vibration controlled structures based on genetic algorithms, Journal of Vibration and Shock, 25, 2, pp. 1-4, (2006)
  • [6] Li C., Xu Z., Zhang L., Earthquake reduction behaviors of active tuned mass dampers for an asymmetric building, Journal of Vibration and Shock, 27, 1, pp. 76-83, (2008)
  • [7] Li H., Huo L., Yan S., TLCD semi-active control for irregular building using neural networks, Earthquake Engineering and Engineering Vibration, 21, 4, pp. 135-141, (2001)
  • [8] Zhang Q., Cao L., Lou W., Parameter optimization of viscoelastic dampers based on the LQR theory, Journal of Vibration and Shock, 24, 2, pp. 62-65, (2005)
  • [9] Li X., Tan P., Liu L., Et al., Parametric optimization and asesmic performance of a TMD system based on power method, Journal of Vibration and Shock, 33, 17, pp. 6-11, (2014)
  • [10] Ziegler F., Mechanics of Solids and Fluids, (1998)