Experimental Study on Mixed Convection Heat Transfer in Rod Bundles

被引:0
|
作者
Liu D. [1 ]
Gu H. [1 ]
机构
[1] School of Nuclear Science and Engineering, Shanghai Jiaotong University, Shanghai
来源
关键词
Buoyancy force; Heat transfer; Mixed convection; Rod bundle;
D O I
10.13832/j.jnpe.2018.03.0013
中图分类号
学科分类号
摘要
With the background of the low flow rate heat transfer in case of the natural circulation in the reactor, the mixed convection was experimentally studied in a 5×5 rod bundles. The experiment was performed at 6 MPa, the mass flow rate from 25 to 150 kg/(m2•s), the heat flux from 25 to 300 kW/m2, Reynolds number from 1000 to 30000, Buoyancy parameter from 2×10-7 to 3×10-3. It is concluded that with the increasing of the Buoyancy parameter, the heat transfer in rod bundles was impaired firstly and then followed by enhancement. It is observed that in the rod bundle channel, the influence of the buoyancy force occurs at Bo*=3.5×10-6. Even when Reynolds number is higher than 15000, the heat transfer could be impaired by the buoyancy force. An empirical correlation used to calculate mixed convection heat transfer in rod bundles was proposed based on the experimental data. © 2018, Editorial Board of Journal of Nuclear Power Engineering. All right reserved.
引用
收藏
页码:13 / 17
页数:4
相关论文
共 6 条
  • [1] Wibisono A.F., Ahn Y., Williams W.C., Et al., Studies of various single phase natural circulation systems for small and medium sized reactor design, Nuclear Engineering and Design, 262, pp. 390-403, (2013)
  • [2] Jackson J.D., Cotton M.A., Axcell B.P., Studies of mixed convection in vertical tubes, International journal of heat and fluid flow, 10, 1, pp. 2-15, (1989)
  • [3] Wu T.H., Xu Z., Jackson J.D., Mixed convection heat transfer to water flowing through a vertical passage of annular cross section: part 2, Chemical Engineering Research and Design, 80, 3, pp. 246-251, (2002)
  • [4] Hallinan K.P., Viskanta R., Heat transfer from a vertical tube bundle under natural circulation conditions, International journal of heat and fluid flow, 6, 4, pp. 256-264, (1985)
  • [5] El-Genk M.S., Su B., Guo Z., Experimental studies of forced, combined and natural convection of water in vertical nine-rod bundles with a square lattice, International journal of heat and mass transfer, 36, 9, pp. 2359-2374, (1993)
  • [6] Todreas N.E., Kazimi M.S., Nuclear Systems: Thermal Hydraulic Fundamentals, (2012)