Fundamental dynamic characteristics of double tuned liquid column damper for suppressing harmonically forced oscillations

被引:0
|
作者
Yan W. [1 ]
Ni M. [1 ]
Wang J. [1 ]
机构
[1] Beijing Laboratory of Earthquake Engineering and Structural Retrofit, Beijing University of Technology, Beijing
来源
| 1600年 / Nanjing University of Aeronautics an Astronautics卷 / 36期
关键词
Double tuned liquid column damper (DTLCD); Double tuned mass damper(DTMD); Effectiveness; Harmonically forced oscillations; Optimization design; Robustness; Vibration control;
D O I
10.16450/j.cnki.issn.1004-6801.2016.06.022
中图分类号
学科分类号
摘要
Taking the advantages of tuned mass damper (TMD) and tuned liquid column dampers (TLCD) in civil engineering vibration control, a double tuned liquid column damper (DTLCD) was presented considering the cost and efficiency of vibration attenuation used in civil engineering. The motion equation of the DTLCD-single-degree-of-freedom (DTLCD-SDOF) system under harmonic excitation was established, of which the dynamic magnification factor (DMF) was derived. Then, an optimization strategy and evaluation function was proposed to judge the parameters of DTLCD, and a parameter optimization program written in Matlab was used to optimize DTLCD. Effects of each parameter on dynamic magnification factor (DMF) were discussed, as well as the robustness of DTLCD when the damping ratio and frequency were changed. Finally, the effectiveness and robustness of DTLCD was compared with that of the TMD, TLCD and DTMD. The theoretical and numerical results showed that the effectiveness of DTLCD was much better than of the TMD and TLCD, and was the same as that of DTMD; meanwhile, DTLCD had the best robustness in terms of perturbation of structure frequency. It was concluded that DTLCD is a very effective method of vibration control. © 2016, Editorial Department of JVMD. All right reserved.
引用
收藏
页码:1175 / 1182
页数:7
相关论文
共 15 条
  • [1] Rana R., Soong T.T., Parametric study and simplified design of tuned mass dampers, World Information on Earthquake Engineering, 14, 4, pp. 91-107, (1998)
  • [2] Gao H., Kwok K.C.S., Optimization of tuned liquid column dampers, Engineering Structures, 19, 6, pp. 476-486, (1997)
  • [3] Yan S., Li H., Et al., Vibration control parameters research on system with adjusted frequency and tuned liquid column damper, Journal of Earthquake Engineering and Engineering Vibration, 18, 4, pp. 96-102, (1998)
  • [4] Xu K., Igusa T., Dynamic characteristics of multiple substructures with closely spaced frequency, Earthquake Engineering and Structural Dynamics, 21, pp. 1059-1070, (1992)
  • [5] Li C., Han B., Du D., Control strategy of double tune mass dampers for structures, China Civil Engineering Journal, 38, 5, pp. 1-9, (2005)
  • [6] Hiroki Y., Napat H., Fundamental characteristics of multiple tuned mass dampers for suppressing harmonically forced oscillations, Earthquake Engineering and Structural Dynamics, 22, pp. 51-62, (1993)
  • [7] Soong T.T., Dargush G.F., Passive Energy Dissipation Systems in Structural Engineering, pp. 1-25, (1997)
  • [8] Zhai W., Li Z., Li G., Et al., Experiment and research on control of wind vibration responses of tall buildings and lofty structures by U-shape water tank, Journal of Building Structures, 14, 5, pp. 37-44, (1993)
  • [9] Yan W., Ji J., Jiang H., A new type pendulous TMD and its application on a tower for wind-induced vibration control, Journal of Building Structures, 31, 2, pp. 55-60, (2010)
  • [10] Zeng S., Ren Y., Cheng T., Et al., Vibration suppression of pipe system with tuned mass damper, Journal of Vibration, Measurement & Diagnosis, 32, 5, pp. 823-826, (2012)