Low Common Mode Interference SVPWM Control for Dual Three Phase Permanent Magnet Synchronous Motor

被引:0
|
作者
Zhang Z. [1 ]
Wu X. [1 ]
Liu X. [2 ]
机构
[1] School of Electrical Engineering, Shenyang University of Technology, Shenyang
[2] State Grid Liaoning Electric Power Co. Ltd, Huludao Electric Power Supply Company, Huludao
关键词
Common mode interference; Dual three phase permanent magnet synchronous motor; Harmonic; Space vector pulse width modulation (SVPWM);
D O I
10.19595/j.cnki.1000-6753.tces.180707
中图分类号
学科分类号
摘要
In order to reduce the common mode interference of dual three-phase permanent magnet synchronous motor (PMSM), a novel space vector pulse width modulation (SVPWM) control strategy is proposed in this paper. Firstly, in the motor driving system, the generation mechanism of the common mode voltage (CMV) is analyzed and discussed. Secondly, based on the voltage vector redundancy of the dual three-phase PMSM, for each sector, the voltage vector combination with lower CMV amplitude and smaller variation frequency is selected, which finally reduces the system common mode interference. Through theoretical analysis and physical experiment, the proposed control strategy can effectively reduce the amplitude of common mode voltage up to 1/6 of the DC bus voltage. Furthermore, the variation frequency of CMV is reduced to 2, so that the system common mode current can be decreased. In addition, from the experiment, it can be seen that there is no obvious increase in the stator current harmonic components when the motor is operating under middle or high-speed condition. © 2018, Electrical Technology Press Co. Ltd. All right reserved.
引用
收藏
页码:58 / 66
页数:8
相关论文
共 18 条
  • [1] Xue S., Wen X., Novel multiphase SVPWM, Transactions of China Electrotechnical Society, 21, 2, pp. 68-73, (2006)
  • [2] Chen B., Li Y., Li Z., Et al., Feature extraction of inchoate interturn short circuit fault for PMSM based on manifold learning, Power System Protection and Control, 44, 17, pp. 18-24, (2016)
  • [3] Meng C., Ouyang H., Liu W., Et al., Space vector PWM techniques for dual Y shift 30 degrees permanent magnet synchronous motor, Proceedings of the CSEE, 30, 3, pp. 90-98, (2010)
  • [4] Chen M., Sun D., A coordinated SVPWM without sector identification for dual inverter fed open winding IPMSM system, IEEE Energy Conversion Congress and Exposition (ECCE), pp. 1-8, (2016)
  • [5] Oscar L., Alvarez J., Malvar J., Et al., Space Vector PWM with Common Mode Voltage Elimination for Multiphase drives, IEEE Transactions on Power Electronics, 31, 12, pp. 8151-8161, (2016)
  • [6] Zhou C., Yang G., Su J., Et al., The control strategy for dual three phase PMSM based on normal decoupling transformation under fault condition due to open phases, Transactions of China Electrotechnical Society, 32, 3, pp. 86-96, (2017)
  • [7] Chen K.Y., Hsieh M.S., Generalized minimum common mode voltage PWM for two-level multiphase VSIs considering reference order, IEEE Transactions on Power Electronics, 32, 8, pp. 6493-6509, (2017)
  • [8] Zheng J., Rong F., Huang S., Et al., Dual Y shift 30° six-phase SVPWM method based on suppression of common mode voltage, Proceedings of the CSEE, 37, 24, pp. 7338-7349, (2017)
  • [9] Huan S., Zhang W., Gao J., Et al., Application of quasi resonant controller for suppressing the common mode voltage of permanent magnet synchronous motor, Transactions of China Electrotechnical Society, 28, 3, pp. 93-98, (2013)
  • [10] Xiao F., Sun L., Sun Y., Et al., Suppression of conducted common mode voltage and shaft voltage in PWM motor drive system, Electric Machines and Control, 13, 3, pp. 402-406, (2009)