On-line monitoring system based on principle of electro-acoustic monitoring for transformer partial discharge

被引:0
|
作者
Liu, Ya Guang [1 ]
Zhang, Xing [1 ]
Kang, Lu [1 ]
机构
[1] Liu, Ya Guang
[2] Zhang, Xing
[3] Kang, Lu
来源
| 1600年 / International Frequency Sensor Association卷 / 165期
关键词
Electrical signal - Electro-acoustic - Monitoring system - On-line monitoring system - Online monitoring - Physical phenomena - Transformer - Transformer diagnosis;
D O I
暂无
中图分类号
学科分类号
摘要
Partial discharge inside a transformer is mainly responsible for the insulation aging and damage of the transformer. However, partial discharge is usually accompanied by external signals like sound, light and electrical signals and detectable physical phenomena such as characteristical gas and dielectric loss. Therefore, it is of great significance to monitor online the external signals and phenomena formed during partial discharge of the transformer when the transformer diagnoses faults. This paper gives a comprehensive overview of the electro-acoustic joint monitoring principles and its monitoring systems and the judgment skills concerned, on the basis of which the monitoring system is designed. © 2014 IFSA Publishing, S. L.
引用
收藏
页码:40 / 45
相关论文
共 50 条
  • [1] On-line Monitoring System for Transformer Partial Discharge
    Liu, Guangya
    Kang, Lu
    Peng, Weina
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 464 - 467
  • [2] Development on the partial discharge on-line monitoring system of transformer based on embedded system
    Zhang Dening
    Zhang Shuguang
    Suo Xuesong
    man, Cheng
    juan, Kou Hong
    ling, Shi Xiang
    su, Zhang
    Li Haiquan
    2008 FOURTH INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATION HIDING AND MULTIMEDIA SIGNAL PROCESSING, PROCEEDINGS, 2008, : 950 - 953
  • [3] On-Line Partial Discharge Monitoring and Diagnostic System for Power Transformer
    林渡
    姜磊
    李福祺
    朱德恒
    谈克雄
    吴成琦
    金显贺
    王昌长
    郑振中
    Tsinghua Science and Technology, 2005, (05) : 598 - 604
  • [4] Partial discharge on-line monitoring system based on FPGA
    Cheng, YH
    Hu, XS
    Chen, XL
    Li, PZ
    PROCEEDINGS OF THE 2005 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, VOLS, 1-3, 2005, : 486 - 489
  • [5] Partial Discharge On-line Monitoring System Based on Acoustic Emission Method - Operational Experiences
    Sikorski, Wojciech
    Walczak, Krzysztof
    Moranda, Hubert
    Gil, Wieslaw
    Andrzejewski, Marek
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11B): : 117 - 121
  • [6] Wavelet method based partial discharge on-line monitoring in high voltage transformer
    Harbin Inst of Technology, Harbin, China
    Dianli Xitong Zidonghue, 4 (19-23):
  • [7] The Design of Multiplexer for on-line Partial Discharge Monitoring System
    Yang, Yuan
    Bi, Jiangang
    Gong, Yanpeng
    Yang, Ning
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2227 - 2231
  • [8] On-line Partial Discharge Monitoring System for Distribution Networks
    Mulroy, Patrick
    Hurtado, Aritz
    Badetz, David
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 542 - 545
  • [9] GIT partial discharge UHF on-line monitoring system
    Zhang, Xiao-Xing
    Wang, Zhen
    Tang, Ju
    Liu, Lei
    Wei, Yan
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1692 - 1697
  • [10] Development of a New On-Line Partial Discharge Monitoring System
    Ohki, Yoshimichi
    IEEE ELECTRICAL INSULATION MAGAZINE, 2020, 36 (04) : 67 - 70