Study on the variation of reactive power when applying the passive filter

被引:0
|
作者
Kim J.-M. [1 ]
Kim J.-G. [1 ]
机构
[1] Dept. of Electrical Engineering, Gangneung-wonju National University
来源
Kim, Jong-Gyeum (jgkim@gwnu.ac.kr) | 1626年 / Korean Institute of Electrical Engineers卷 / 65期
关键词
Harmonics current; Linear load; Load; Non-linear; Passive filter; Power factor; Reactive power;
D O I
10.5370/KIEE.2016.65.9.1626
中图分类号
学科分类号
摘要
Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:1626 / 1631
页数:5
相关论文
共 50 条
  • [1] Advanced configuration of hybrid passive filter for reactive power and harmonic compensation
    Kececioglu, O. Fatih
    Acikgoz, Hakan
    Sekkeli, Mustafa
    SPRINGERPLUS, 2016, 5
  • [2] Study on Passive Filter in Wind Power Converter
    Zhai, Wei
    Shi, Lei
    Sun, Zu Yong
    2013 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2013, : 229 - 232
  • [3] Improved Direct Power Control of Shunt Active Power Filter with Minimum Reactive Power Variation and Minimum Apparent Power Variation Approaches
    Trivedi, Tapankumar
    Jadeja, Rajendrasinh
    Bhatt, Praghnesh
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (03) : 1124 - 1136
  • [4] Hybrid active power filter with the reduced passive filter
    Bula, Dawid
    Maciazek, Marcin
    Pasko, Marian
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (06): : 1 - 4
  • [5] Hybrid power filter with single tuned passive filter
    Bula, Dawid
    Pasko, Marian
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (12): : 174 - 179
  • [6] Hybrid power filter with single tuned passive filter
    Bula, Dawid
    Pasko, Marian
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (03): : 205 - 210
  • [7] Parallel operation of passive power filter and hybrid power filter for harmonic suppression
    Jou, HL
    Wu, JC
    Wu, KD
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (01) : 8 - 14
  • [8] A study on the control method of series active power filter for compensation of harmonies and reactive power
    Kim, YS
    Kim, JS
    Ko, SH
    ICEMS 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1 AND 2, 2003, : 457 - 460
  • [9] Study on application of hybrid active power filter into harmonic suppression and reactive power compensation
    Wu Wei-nong
    He Na
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [10] A quasi passive filter for power quality improvement
    Kapoor, AK
    Mahanty, R
    PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY 2000, VOLS 1 AND 2, 2000, : 526 - 529