Development of real-time thermal neutron flux monitor during boron neutron capture therapy

被引:0
|
作者
Ishikawa, M.
Ono, K.
Unesaki, H.
Kobayashi, T.
Sakurai, Y.
Tanaka, K.
Kosako, T.
机构
[1] Res. Ctr. Nucl. Sci. and Technology, University of Tokyo, Japan
[2] Research Reactor Institute, Kyoto University, Japan
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Development of real-time thermal neutron monitor using boron-loaded plastic scintillator with optical fiber for boron neutron capture therapy
    Ishikawa, M
    Ono, K
    Sakurai, Y
    Unesaki, H
    Uritani, A
    Bengua, G
    Kobayashi, T
    Tanaka, K
    Kosako, T
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 775 - 779
  • [2] Development of real-time epithermal neutron detector for boron neutron capture therapy
    Tanaka, H.
    Sakurai, Y.
    Takata, T.
    Watanabe, T.
    Kawabata, S.
    Suzuki, M.
    Masunaga, S. -I.
    Taki, K.
    Akabori, K.
    Watanabe, K.
    Ono, K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (05):
  • [3] Real-time neutron beam monitor utilizing scintillator technology for boron neutron capture therapy
    Jeon, Sang June
    Choi, Jaewon
    Lee, Kyu Young
    Yi, Jungyu
    RADIATION MEASUREMENTS, 2024, 172
  • [4] REAL-TIME DOSIMETRY FOR BORON NEUTRON-CAPTURE THERAPY
    BLISS, M
    CRAIG, RA
    REEDER, PL
    SUNBERG, DS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 639 - 643
  • [5] Design of an epi-thermal neutron flux intensity monitor with GaN wafer for boron neutron capture therapy
    School of Nuclear Science and Technology, Lanzhou University, Lanzhou
    Gansu Province
    730000, China
    不详
    565-0871, Japan
    J. Nucl. Sci. Technol., 1600, 4 (503-508):
  • [6] Design of an epi-thermal neutron flux intensity monitor with GaN wafer for boron neutron capture therapy
    Guan, Xingcai
    Manabe, Masanobu
    Murata, Isao
    Wang, Tieshan
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2015, 52 (04) : 503 - 508
  • [7] Development of a real-time neutron beam detector for boron neutron capture therapy using a thin silicon sensor
    Takada, Masashi
    Nunomiya, Tomoya
    Masuda, Akihiko
    Matsumoto, Tetsuro
    Tanaka, Hiroki
    Nakamura, Satoshi
    Endo, Satoru
    Nakamura, Masaru
    Aoyama, Kei
    Ueda, Osamu
    Narita, Masataka
    Nakamura, Takashi
    APPLIED RADIATION AND ISOTOPES, 2021, 176
  • [8] Development of two dimensional thermal neutron flux monitor using multi-wire proportional counter for boron neutron capture therapy
    Tanaka, Hiroki
    Sakurai, Yoshinori
    Suzuki, Minoru
    Masunaga, Shin-ichiro
    Hino, Masahiro
    Kinashi, Yuko
    Ono, Koji
    Maruhashi, Akira
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 185 - 187
  • [9] Development of Thermal Neutron Flux Monitor U sing Small Scintillator Array Coupled with Quartz Fibers for Boron Neutron Capture Therapy
    Tanaka, Hiroki
    Sakurai, Yoshinori
    Suzuki, Minoru
    Masunaga, Shinichiro
    Kinashi, Yuko
    Kondo, Natsuko
    Kawabata, Yuji
    Yagi, Takahiro
    Misawa, Tsuyoshi
    Ono, Koji
    Maruhashi, Akira
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 416 - 418
  • [10] Characterization of a real-time neutron detector for boron neutron capture therapy using a thin silicon diode
    Takada, Masashi
    Nunomiya, Tomoya
    Masuda, Akihiko
    Matsumoto, Tetsuro
    Tanaka, Hiroki
    Nakamura, Satoshi
    Endo, Satoru
    Nakamura, Masaru
    Aoyama, Kei
    Ueda, Osamu
    Narita, Masataka
    Nakamura, Takashi
    RADIATION MEASUREMENTS, 2020, 137