AC flashover performance and voltage correction of iced 10 kV composite insulator in high altitude area

被引:0
|
作者
Tian, Yuchun
Jiang, Xingliang
Shu, Lichun
Sima, Wenxia
Sun, Caixin
机构
来源
| 2002年 / Science Press卷 / 28期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] AC flashover performance and voltage correction of 27.5 and 110 kV iced composite insulator at 4000-5,500 m high altitude districts
    Jiang, XL
    Sun, CX
    Sima, WX
    Tian, YC
    Shu, LC
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1890 - 1894
  • [2] DC flashover performance of ±800 kV composite post insulator in high altitude area
    Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
    Gaodianya Jishu, 2009, 4 (749-754):
  • [3] Flashover performance and voltage correction of iced and polluted HV insulator string at high altitude of 4000m and above
    Sun, CX
    Tian, YC
    Jiang, XL
    Shu, LC
    Sima, WX
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 141 - 145
  • [4] AC flashover performance of natural iced insulators in high altitude regions
    Shu, LC
    Jiang, XL
    Mei, BX
    Hu, Q
    Yang, Q
    PROCEEDINGS OF THE FOURTEENTH (2004) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1, 2004, : 940 - 944
  • [5] Equivalence of pollution simulation methods for AC flashover performance of iced composite insulator
    Jiang, Xing-Liang
    Zhang, Zhi-Jin
    Hu, Jian-Lin
    Yang, Jian-Lan
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (13): : 115 - 120
  • [6] AC flashover performance of artificial iced and polluted insulators at high altitude districts
    Shu, LC
    Jiang, XL
    Sun, CX
    Tian, YC
    Farzaneh, M
    Li, Y
    Zhang, JH
    PROCEEDINGS OF THE THIRTEENTH (2003) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1, 2003, : 403 - 408
  • [8] Influence of length and arrangement of iced insulator strings on DC flashover voltage at high altitude districts
    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400030, China
    Zhongguo Dianji Gongcheng Xuebao, 2008, 3 (1-5):
  • [9] AC flashover performance and voltage of long polluted and iced XP-70 suspension insulator string
    Jiang, XL
    Sun, CX
    Shu, LC
    Sima, WX
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 158 - 161
  • [10] AC withstand voltage performance of 110kV iced composite insulators
    Hu, JL
    Shu, LC
    Sun, CX
    Jiang, XL
    Sima, WX
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 343 - 346