Detection of Heavy Metal Ions by Differential Pulse Stripping Voltammetry

被引:0
|
作者
Sun P. [1 ,2 ]
Yan M.-G. [2 ]
Zhang H.-Z. [2 ]
Huang Q. [2 ]
Zhou L. [2 ]
Zhao Y. [2 ]
Peng F.-G. [2 ]
Liu P.-L. [2 ]
机构
[1] College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu
[2] College of Science, Sichuan Agriculture University, Ya'an, 625014, Sichuan
来源
| 1600年 / Univ. of Electronic Science and Technology of China卷 / 46期
关键词
Differential pulse stripping voltammetry; Glassy carbon electrode; Heavy metal ions; Mercury membrame;
D O I
10.3969/j.issn.1001-0548.2017.05.022
中图分类号
学科分类号
摘要
The differential pulse stripping voltammetry is used to detect the lead and cadmium heavy metal ions in liquid phase. The experimental parameters can be gradually optimized by changing the experimental conditions. The experimental results are analyzed and discussed. The detection limits for lead and cadmium ions are 0.54 g/L, 0.79 g/L, respectively, and the linear correlation coefficient of cadmium reaches to 0.999 7.The voltammetry used here has merits such as high sensitivity, easy operation, simple structure, low pollution, repeatable measurement, and show potential application for real-time monitoring of heavy metal ions. © 2017, Editorial Board of Journal of the University of Electronic Science and Technology of China. All right reserved.
引用
收藏
页码:784 / 789
页数:5
相关论文
共 18 条
  • [1] Brown R.J.C., Milton M.J.T., Analytical techniques for trace element analysis: an overview, Trac Trends in Analytical Chemistry, 24, 3, pp. 266-274, (2005)
  • [2] Kefala G., Economou A., Voulgaropoulos A., Et al., A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair, Talanta, 61, 61, pp. 603-610, (2003)
  • [3] Lai R., Qiu F.-B., Xu Z.-G., Et al., Determination of copper, lead and cadmium in food by microwave digestion-anodic stripping voltammetry, Journal of Instrumental Analysis, 29, 2, pp. 203-206, (2010)
  • [4] Gao H.-Y., Sun J.-L., Li N., Determination of cadmium in a water sample with anodic stripping square wave voltammetry, Journal of Ili Normal University (Natural Scienc Edition), 2, pp. 31-33, (2008)
  • [5] Deng T.-L., Liao M.-X., Continuous determination of Ca Pb polarography, Chinese Journal of Analytical Chemistry, 11, (1998)
  • [6] Song G.-J., Wei X.-P., Determination of Pb<sup>2+</sup> and Cd<sup>2+</sup> in sludge samples by potential stripping analysis, Guangxi Sciences, 10, 2, (2003)
  • [7] Yu Q.-K., Li D., Determination of Cu, Pb, Cd, Zn in sea water by anodic stripping voltammetry, Chemical Engineer, 10, pp. 25-27, (2009)
  • [8] Sahlin E., Jagner D., Ratana-Ohpas R., Mercury nucleation on glassy carbon electrodes, Analytica Chimica Acta, 346, 2, pp. 157-164, (1997)
  • [9] Farghaly O.A., Direct and simultaneous voltammetric analysis of heavy metals in tap water samples at Assiut city: an approach to improve the analysis time for nickel and cobalt determination at mercury film electrode, Microchemical Journal, 75, 2, pp. 119-131, (2003)
  • [10] Ensafi A.A., Nazari Z., Fritsch I., Highly sensitive differential pulse voltammetric determination of Cd, Zn and Pb ions in water samples using stable carbon-based mercury thin-film electrode, Electroanalysis, 22, 21, pp. 2551-2557, (2010)