A development of the fault detection system of wire rope using magnetic flux leakage inspection method and noise filter

被引:3
|
作者
Dept. of Aviation Control System, Korea Aviation Polytechnic Colleges, Korea, Republic of [1 ]
不详 [2 ]
机构
来源
关键词
Wire rope - Bandpass filters - Signal processing - Timing circuits - Accidents - Data acquisition - Hall effect transducers;
D O I
10.5370/KIEE.2014.63.3.418
中图分类号
学科分类号
摘要
A large number of wire rope has been used in various industries such as cranes and elevators. When wire used for a long time, wire defects occur such as disconnection and wear. It leads to an accident and damage to life and property. To prevent this accident, we proposed a wire rope fault detection system in this paper. We constructed the whole system choosing the leakage fault detection method using hall sensors and the method is simple and easy maintenance characteristics. Fault diagnosis and analysis were available through analog filter and amplification process. The amplified signal is transmitted to the computer through the data acquisition system. This signal could be obtained improved results through the digital filter process.
引用
收藏
相关论文
共 50 条
  • [1] Quantitative Inspection of Wire Rope Discontinuities using Magnetic Flux Leakage Imaging
    Zhang, Donglai
    Zhao, Min
    Zhou, Zhihui
    MATERIALS EVALUATION, 2012, 70 (07) : 872 - 878
  • [2] Magnetic Flux Leakage Testing of Wire Rope Defects with Denoising
    Zhang, Enchao
    Zhang, Donglai
    Pan, Shimin
    PROCEEDINGS OF 2019 IEEE 3RD INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC 2019), 2019, : 1574 - 1577
  • [3] Testing Method and Experiment of Magnetic Flux Leakage of Spiral Rising Steel Wire Rope
    Lu, Jialei
    Ma, Kaiwei
    Shi, Wei
    Xu, Fengyu
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2021, PT I, 2021, 13013 : 232 - 240
  • [4] A new measurement system using magnetic flux leakage method in pipeline inspection
    Ege, Yavuz
    Coramik, Mustafa
    MEASUREMENT, 2018, 123 : 163 - 174
  • [5] MAGNETIC-FLUX LEAKAGE INSPECTION OF WIRE ROPES
    BERGANDER, M
    MATERIALS EVALUATION, 1981, 39 (10) : A14 - A14
  • [6] Research of Non-destructive Testing of Wire Rope Using Magnetic Flux Leakage
    Zhong Xiao-yong
    Zhang Xiao-hong
    FRONTIER IN INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS, 2012, 189 : 255 - +
  • [8] Broken wire detection in coated steel belts using the magnetic flux leakage method
    Lei, Hua-Ming
    Tian, Gui-Yun
    INSIGHT, 2013, 55 (03) : 126 - 131
  • [9] Analysis of the Eccentric Problem of Wire Rope Magnetic Flux Leakage Testing
    Pan, Shimin
    Zhang, Donglai
    Zhang, Enchao
    PROCEEDINGS OF 2019 IEEE 3RD INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC 2019), 2019, : 1597 - 1601
  • [10] A new method of deflects identification for wire rope based on three-dimensional magnetic flux leakage
    Zhang, D. L.
    Cao, Y. N.
    Wang, C.
    Xu, D. G.
    4TH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY (ISIST' 2006), 2006, 48 : 334 - 338