Unit leading-phase capability simulation based on modified auxiliary power model for thermal power plant

被引:0
|
作者
Tang Y. [1 ]
Dai Y. [1 ]
Chen B. [1 ]
Wang C. [2 ]
机构
[1] School of Electrical Engineering, Southeast University, Nanjing
[2] Jiangsu Electric Power Research Institute, Nanjing
来源
| 2016年 / Electric Power Automation Equipment Press卷 / 36期
基金
中国国家自然科学基金;
关键词
Auxiliary power; Leading-phase capability; Simulative test; Static load model; Thermal power plant;
D O I
10.16081/j.issn.1006-6047.2016.12.010
中图分类号
学科分类号
摘要
Aiming at the large error and simple test condition of traditional method for determining the unit leading-phase capability, a method for simulating the unit leading-phase capability of thermal power plant is proposed based on the static auxiliary power model. A modified static auxiliary power model is put forward, which applies the method of parameter identification based on the actual operating data of power plant. The auxiliary power model is built on PSD-BPA software platform to simulate the unit leading-phase depth in different operational conditions when the voltage limit of auxiliary power or the static stability limit of unit is reached. The measured data of a 1000 MW unit from June 2013 to June 2015 are applied to calculate its leading-phase capability. The simulative results are compared with the measured data of its leading-phase test, verifying the effectiveness and rationality of the proposed method. © 2016, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:63 / 68and108
相关论文
共 16 条
  • [1] Wang C., Wang H., Review of synchronous generator leading-phase operation, Electric Power Automation Equipment, 32, 11, pp. 131-135, (2012)
  • [2] Wei Y., Wei Z., Zhang Y., Et al., Progress and development trend on leading phase of generator, Power System Protection and Control, 40, 9, pp. 146-154, (2012)
  • [3] Pu Q., Zhang Y., Chen L., Et al., Generator's leading phase operation and emergency voltage control of capacitive isolated network, Power System Protection and Control, 40, 18, pp. 24-29, (2012)
  • [4] Yang Y., Li Y., Li L., Et al., Analysis and countermea-sures for volt/var control in Guangdong Power Grid during the period of Spring Festival, Power System Technology, 31, pp. 135-138, (2007)
  • [5] Xu B., Shan Z., Leading phase operation present situation and analysis of Hunan Power Grid's generators, Hunan Electric Power, 31, pp. 50-53, (2011)
  • [6] Mou T., Song D., Ye F., Capability study on generator leading operation considering static stability limit, Northeast Electric Power Technology, 10, pp. 7-10, (2010)
  • [7] Liu H., Analysis and discussion on generator leading-phase test, Guangxi Electric Power, 38, 2, pp. 43-45, (2015)
  • [8] Zhai X., Wei Z., Fan L., Et al., Generator leading phase capability model based on relevance vector machine, Electric Power Automation Equipment, 35, 3, pp. 146-151, (2015)
  • [9] Li Z., He F., Chao H., Et al., Numerical analysis of steady state stability limit of salient synchronous generator in leading power factor operation test, Electric Machines and Control, 15, 12, pp. 89-95, (2011)
  • [10] Shi J., Shi Y., Zhao X., Et al., The new method of determining the capability of leading phase of generator and realizing the online monitoring, Proceedings of the CSEE, 26, 11, pp. 139-143, (2006)