Metal artifact reduction for dental implants in kilovoltage computed tomography using megavoltage cone-beam computer tomography

被引:0
|
作者
Gao, Liugang [1 ]
Sun, Hongfei [1 ]
Lin, Tao [1 ]
Sui, Jianfeng [1 ]
Ni, Xinye [1 ]
机构
[1] Department of Radiation Oncology, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou,Jiangsu,213003, China
关键词
462.3 Dental Equipment and Supplies - 723.5 Computer Applications;
D O I
暂无
中图分类号
学科分类号
摘要
19
引用
收藏
页码:730 / 737
相关论文
共 50 条
  • [1] Metal Artifact Reduction in Helical Cone-beam Computed Tomography
    Tang, Jie
    Zhang, Li
    Chen, Zhiqiang
    Xing, Yuxiang
    Cheng, Jianping
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2878 - 2881
  • [2] Megavoltage and Kilovoltage Cone-Beam Computed Tomography Image Guidance for Lung Radiotherapy
    Vlad, M.
    Sixel, K.
    Kosowan, S.
    Hart, M.
    Iqbal, F.
    El-Mallah, M.
    Vandermeer, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Developments of Metal Artifact Reduction Methods for Cone-beam Computed Tomography
    Shih, Kun-Long
    David
    Jin, Shih-Chun
    Chen, Jyh-Cheng
    MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214
  • [4] Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy
    Korpics, Mark
    Johnson, Paul
    Patel, Rakesh
    Surucu, Murat
    Choi, Mehee
    Emami, Bahman
    Roeske, John C.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP88 - NP94
  • [5] The efficacy of metal artifact reduction (MAR) algorithm in cone-beam computed tomography on the diagnostic accuracy of fenestration and dehiscence around dental implants
    Sheikhi, Mahnaz
    Behfarnia, Parichehr
    Mostajabi, Mahdis
    Nasri, Naeimeh
    JOURNAL OF PERIODONTOLOGY, 2020, 91 (02) : 209 - 214
  • [6] Postoperative Assessment of Incisor Dental Implants Using Cone-Beam Computed Tomography
    Naitoh, Munetaka
    Nabeshima, Hiromitsu
    Hayashi, Hisashi
    Nakayama, Takehiko
    Kurita, Kenichi
    Ariji, Eiichiro
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (05) : 377 - 384
  • [7] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [8] The Effect of Changes in the Angular Position of Implants on Metal Artifact Reduction in Cone-Beam Computed Tomography Images: A Scoping Review
    Asnaashari, Maedeh
    Sadeghipour, Maryam
    Bahrani, Zeinab
    Valizadeh, Solmaz
    Moshfeghi, Mahkameh
    RADIOLOGY RESEARCH AND PRACTICE, 2023, 2023
  • [9] A computational investigation for metal artifact reduction in cone-beam X-ray computed tomography
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    2006 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES,VOLS 1-3, 2006, : 376 - +
  • [10] Influence of kilovoltage- peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
    Fontenele, Rocharles Cavalcante
    Nascimento, Eduarda Helena Leandro
    Imbelloni-Vasconcelos, Ana Catarina
    Martins, Luciano Augusto Cano
    Pontual, Andrea dos Anjos
    Ramos-Perez, Flavia Maria Moraes
    Freitas, Deborah Queiroz
    IMAGING SCIENCE IN DENTISTRY, 2022, : 267 - 273