Transient analysis of grid short circuit fault of megawatt doubly fed wind turbine

被引:0
|
作者
Lü, Zhi-Qiang [1 ]
Xu, Guo-Dong [1 ]
机构
[1] Zhejiang Windey Engineering Co., Ltd., Hangzhou 310012, China
关键词
Analysis and simulation - Crow-bar circuit - Doubly fed induction generator (DFIG) - Response calculation - Short-circuit fault - Stator transients - Three-phase short circuit faults - Transient equation;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:112 / 116
相关论文
共 50 条
  • [1] Torsional fatigue reliability analysis of doubly-fed wind turbine drivetrain under power grid with short circuit fault
    Qiu, Shilong
    Li, Hui
    Gong, Lijiao
    Wang, Bin
    Chai, Zhaosen
    Si, Jindong
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (02): : 380 - 388
  • [2] Analysis of short circuit current of wind turbine - Doubly fed induction generator
    Li, D. D.
    [J]. 2006 1st IEEE Conference on Industrial Electronics and Applications, Vols 1-3, 2006, : 920 - 924
  • [3] Analysis of short circuit current of wind turbine - Doubly fed induction generator
    Li, D. D.
    [J]. ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1082 - 1086
  • [4] Transient Responses of the Doubly-Fed Induction Generator Wind Turbine under Grid Fault Conditions
    Phan, T. T.
    Nguyen, V. L.
    Hossain, M. J.
    To, A. N.
    Tran, H. T.
    Phan, T. N.
    [J]. 2016 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND APPLICATIONS (ACOMP), 2016, : 97 - 104
  • [5] Analysis and Experiment Research on Transient Behavior of Flexible Drive Train for Doubly-fed Wind Turbine under Grid Fault
    Li, Shaolin
    Wang, Ruiming
    Chen, Chen
    Wang, Yingying
    Wang, Wenzhuo
    [J]. 2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [6] Fault Diagnosis of Stator Inter-Turn Short Circuit in Doubly Fed Induction Generator of Wind Turbine
    Idrissi, Imam
    El Bachtiri, Rachid
    Chafouk, Houcine
    Khanfara, Maha
    [J]. 2019 6TH INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT 2019), 2019, : 1313 - 1318
  • [7] Model of stator inter-turn short circuit fault in doubly-fed induction generators for wind turbine
    Lu, QF
    Cao, ZT
    Ritchie, E
    [J]. PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 932 - 937
  • [8] Analysis of Short Circuit Faults in a System Fed by Wind Turbine
    Nayir, Ahmet
    Rosolowski, Eugeniusz
    Jedut, Leszek
    [J]. INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [9] Grid Fault Performance of Brushless Doubly-Fed Reluctance Machines in Wind Turbine Applications
    Gay, D.
    Betz, R. E.
    Dorrell, D.
    Knight, A.
    [J]. 2018 20TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'18 ECCE EUROPE), 2018,
  • [10] Analytical Study of Grid-Fault Response of Wind Turbine Doubly Fed Induction Generator
    Pannell, Graham
    Atkinson, David J.
    Zahawi, Bashar
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (04) : 1081 - 1091