Quantifying particulate matter emission rates from naturally ventilated dairy buildings by considering roof opening contributions

被引:0
|
作者
Lu, Yujian [1 ,2 ]
Yang, Xiao [1 ,3 ]
Xiao, Pan [1 ,3 ]
Lei, E. [1 ,3 ]
Wang, Chaoyuan [1 ,3 ]
Yu, Jing [4 ]
Liang, Chao [1 ,3 ]
Fang, Zhiwei [1 ,3 ]
Li, Yongzhen [1 ,3 ]
机构
[1] China Agr Univ, Coll Water Resources & Civil Engn, Dept Agr Struct & Bioenvironm Engn, Beijing 100083, Peoples R China
[2] Henan Agr Univ, Coll Anim Sci & Technol, Zhengzhou 450046, Peoples R China
[3] Minist Agr & Rural Affairs, Key Lab Agr Engn Struct & Environm, Beijing 100083, Peoples R China
[4] Tianjin Mengde Grp Co Ltd, Tianjin 300403, Peoples R China
来源
ATMOSPHERIC ENVIRONMENT-X | 2024年 / 24卷
基金
中国国家自然科学基金;
关键词
Emission rate; Dairy cow; Particulate matter; Sidewall opening; Spatiotemporal variation; AIR EXCHANGE-RATES; AMMONIA EMISSIONS; LIVESTOCK BUILDINGS; SCALE-MODEL; METHODOLOGY; FLOWS;
D O I
10.1016/j.aeaoa.2024.100299
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Roof openings are typically fitted to naturally ventilated dairy building (NVDB) for better ventilation but their impact on air pollutant emission calculations has not been fully considered. Particulate matter (PM) emission rate (ER) for NVDB rely on the total ventilation rate (VR), outdoor PM concentration and average indoor PM concentration sampled either under the roof (Roof Sampling) or in the cubicle area (Cubicle Sampling), which may show large deviations due to its spatiotemporal variation of PM concentrations and complex airflow patterns. This study utilised a novel ER calculation method (Joint Sampling) that computes the respective emission from the roof and sidewall openings by matching each outlet's VR and PM concentration. By year-round field measurements of PM2.5 and the total suspended particulates (TSP), results showed that annual average ERs of PM2.5 and TSP were 10.8 mg h- 1 cow- 1 and 45.7 mg h- 1 cow-1 for Roof Sampling, 12.7 mg h- 1 cow-1 and 40.7 mg h- 1 cow-1 for Cubicle Sampling, and 11.7 mg h- 1 cow- 1 and 45.9 mg h- 1 cow-1 for Joint Sampling. Considering the Joint Sampling results were relatively true, Roof Sampling exhibited a maximum underestimate of PM2.5 emissions of 20.8% when sidewall curtains were fully opened, whilst Cubicle Sampling demonstrated a maximum overestimate of TSP of 10.2% when the aperture was closed. Using Joint Sampling, the roof opening contributed 39.3% and 24.4% of the annual PM2.5 and TSP emissions. When sidewall openings are partially or fully closed, the Joint Sampling calculation is preferable to estimate the ER of PM.
引用
收藏
页数:9
相关论文
共 44 条
  • [1] Transport process of outdoor particulate matter into naturally ventilated buildings
    Chu, Chia-Ren
    Yang, Kai-Jie
    BUILDING AND ENVIRONMENT, 2022, 207
  • [2] Particulate matter dynamics in naturally ventilated freestall dairy barns
    Joo, H. S.
    Ndegwa, P. M.
    Heber, A. J.
    Ni, J. -Q.
    Bogan, B. W.
    Ramirez-Dorronsoro, J. C.
    Cortus, E. L.
    ATMOSPHERIC ENVIRONMENT, 2013, 69 : 182 - 190
  • [3] Diurnal variation of ammonia emission from naturally ventilated dairy cattle buildings
    Zhang, G.
    Strom, J. S.
    Wang, C.
    Rom, H. B.
    Morsing, S.
    LIVESTOCK ENVIRONMENT VII, PROCEEDINGS, 2005, : 419 - 428
  • [4] Emission of ammonia and other contaminant gases from naturally ventilated dairy cattle buildings
    Zhang, G
    Strom, JS
    Li, B
    Rom, HB
    Morsing, S
    Dahl, P
    Wang, C
    BIOSYSTEMS ENGINEERING, 2005, 92 (03) : 355 - 364
  • [5] Measurement of particulate matter emission rates from mechanically ventilated swine barns
    Predicala, BZ
    Maghirang, RG
    TRANSACTIONS OF THE ASAE, 2004, 47 (02): : 557 - 565
  • [6] Mitigating particulate matter exposure in naturally ventilated buildings during haze episodes
    Tham, K. W.
    Parshetti, G. K.
    Balasubramanian, R.
    Sekhar, C.
    Cheong, D. K. W.
    BUILDING AND ENVIRONMENT, 2018, 128 : 96 - 106
  • [7] SAMPLING DURATION AND FREQUENCY FOR DETERMINING EMISSION RATES FROM NATURALLY VENTILATED DAIRY BARNS
    Kafle, G. K.
    Joo, H. S.
    Ndegwa, P. M.
    TRANSACTIONS OF THE ASABE, 2018, 61 (02) : 681 - 691
  • [8] Estimation of opening discharge coefficient of naturally ventilated dairy buildings by response surface methodology
    Yi, Qianying
    Zhang, Guoqiang
    Li, Hao
    Wang, Xiaoshuai
    Janke, David
    Amon, Barbara
    Hempel, Sabrina
    Amon, Thomas
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2020, 169 (169)
  • [9] Model estimation and measurement of ammonia emission from naturally ventilated dairy cattle buildings with slatted floor designs
    Department of Agricultural Structure and Bio-Environmental Engineering, China Agricultural University, Beijing, China
    不详
    不详
    J. Air Waste Manage. Assoc., 2006, 9 (1252-1259):
  • [10] Model estimation and measurement of ammonia emission from naturally ventilated dairy cattle buildings with slatted floor designs
    Wang, Chaoyuan
    Li, Baoming
    Zhang, Guoqiang
    Rom, Hans Benny
    Strom, Jan S.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2006, 56 (09) : 1252 - 1259