The effects of surface and absorbed fabrication residues on an assembler for electric leakage were examined. The integrated circuit analysis for the soldermasked FR-4 boards was carried out. The results showed that inconsistent performance during burn-in-testing were mainly due to the presence of anion and cation residues on bare boards and incomplete board cleaniness that left high levels of chlorides. A remedial cleaning process was recommended for the burn-in-leakage problems.