Radiographic comparison of grit-blasted hydroxyapatite and arc-deposited hydroxyapatite acetabular components: A four-year follow-up study

被引:0
|
作者
机构
[1] Jazrawi, L.M.
[2] Adler, E.M.
[3] Jazrawi, A.J.
[4] Jaffe, W.L.
来源
Jaffe, W.L. | 2000年 / J. Michael Ryan Publishing Inc.卷 / 59期
关键词
Biocompatibility; -; Biomaterials; Bone; Hydroxyapatite; Radiography;
D O I
暂无
中图分类号
学科分类号
摘要
High rates of aseptic loosening have been reported for microstructured hydroxyapatite-coated acetabular components. A macrostructured component surface (arc-deposition) not only improves resistance to shear forces experienced by the acetabular component and increases initial stability, but also provides channels for bone ingrowth. The purpose of this investigation was to radiographically compare a series of grit-blasted (microstructured) and arc-deposited (macrostructured) hydroxyapatite-coated acetabular components. A minimum 4-year retrospective radiographic analysis of acetabular components was performed on a total of 50 total hip arthroplasties. At 4 years, arc-deposited components were associated with fewer radiolucent lines in all Charnley zones, particularly Charnley zone III. While the 4-year results for arc-deposited hydroxyapatite acetabular components are superior to their microstructured predecessors, long-term results are still unknown.
引用
收藏
相关论文
共 50 条
  • [1] Grit-blasted and hydroxyapatite-coated total hip arthroplasty: an 11-to 14-year follow-up study
    Miyakawa, S
    Kawamura, H
    Mishima, H
    Yasumoto, J
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (05) : 462 - 467
  • [2] Total Hip Arthroplasty Using Cementless Grit-Blasted Femoral Component A Minimum 10-Year Follow-Up Study
    Hwang, Kyu-Tae
    Kim, Young-Ho
    Kim, Yee-Suk
    Choi, Il-Yong
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 1554 - 1561
  • [3] Prevention of osteoporosis -: Four-year follow-up of a cohort of postmenopausal women treated with an ossein-hydroxyapatite compound
    Fernandez-Pareja, Antonio
    Hernandez-Blanco, Elena
    Manuel Perez-Maceda, Jose
    Jose Riera Rubio, Vicente
    Haya Palazuelos, Javier
    Manasanch Dalmau, Jose
    [J]. CLINICAL DRUG INVESTIGATION, 2007, 27 (04) : 227 - 232
  • [4] Minimum 10-year follow-up of micro-arc oxidation coating on a cementless grit-blasted tapered-wedge stem of total hip arthroplasty: a multicentre study
    Lim, Young-Wook
    Song, Joo-Hyoun
    Kwon, Soon-Yong
    Kim, Yong-Sik
    Byun, Young-Seol
    Lee, Se-Won
    [J]. HIP INTERNATIONAL, 2022, 32 (04) : 501 - 509
  • [5] Slowly progressive aphasia: a four-year follow-up study
    Papagno, C
    Capitani, E
    [J]. NEUROPSYCHOLOGIA, 2001, 39 (07) : 678 - 686
  • [6] Dementia as a predictor of functional disability: A four-year follow-up study
    Sauvaget, C
    Yamada, M
    Fujiwara, S
    Sasaki, H
    Mimori, Y
    [J]. GERONTOLOGY, 2002, 48 (04) : 226 - 233
  • [7] Happy aging: A representative national four-year follow-up study
    Kopp, M.
    [J]. PSYCHOLOGY & HEALTH, 2010, 25 : 49 - 50
  • [8] Four-year follow-up of the European tacrolimus multicenter renal study
    Mayer, AD
    [J]. TRANSPLANTATION PROCEEDINGS, 1999, 31 (7A) : 27S - 28S
  • [9] Four-Year Follow-Up Study of Pharmacological Treatment in Pathological Gamblers
    Rosenberg, Oded
    Dinur, Limor Klein
    Dannon, Pinhas N.
    [J]. CLINICAL NEUROPHARMACOLOGY, 2013, 36 (02) : 42 - 45
  • [10] Cognitive behavioral therapy: A four-year follow-up study of anorexics
    RomoJimenez, L
    SamuelLajeunesse, B
    Foulon, C
    Divac, S
    [J]. INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1996, 31 (3-4) : 54142 - 54142