The minimization of generator output variations by impulse chamber pressure control during turbine valve test

被引:0
|
作者
Choi, In-Kyu
Kim, Jong-An
Park, Doo-Yong
Woo, Joo-Hee
Shin, Jae-Ho
机构
关键词
Pressure control - Steam - Steam power plants - Nuclear power plants - Plant shutdowns - Nuclear fuels - Safety valves - Turbines;
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes the actual application of a feedback control loop as a means for minimizing turbine impulse chamber pressure variation during the turbine steam valve tests at a 1,000 MW nuclear power plant. The chamber pressure control loop was implemented in the new digital control system which was installed as a replacement for the old analog type control system. There has been about 40MW of the generator output change during the steam valve tests, especially the high pressure governing valve tests, because the old control system had not the impulse chamber pressure control so the operators had to compensate steam flow drop manually. The process of each valve test consists of a closing process and an reopening process and the operators can make sure, that the valves are in their sound conditions by checking the valves movement. The control algorithm described in this paper contributed to keep the change in megawatt only to 6MW during the steam valve tests. Thereby, the disturbance to reactor control was reduced, and the overall plant control system's stability was greatly improved as well.
引用
收藏
页码:152 / 159
相关论文
共 50 条
  • [1] Control system for the impulse generator and test
    Xia, Y.L.
    Yu, J.H.
    Li, X.C.
    Gaodianya Jishu/High Voltage Engineering, 2001, 27 (02):
  • [2] THE IMPACT OF SHAPE ADJUSTMENTS OF A VALVE CHAMBER ON LOSSES IN THE CONTROL VALVE OF THE STEAM TURBINE
    Bednar, L.
    Tajc, L.
    Miczan, M.
    Hoznedl, M.
    Kocarnik, P.
    Jirku, S.
    ENGINEERING MECHANICS 2016, 2016, : 54 - 57
  • [3] OPTIMIZATION OF DIMENSIONS OF THE VALVE CHAMBER OF THE CONTROL VALVES OF STEAM TURBINE
    Bednar, L.
    Tajc, L.
    Kocarnik, P.
    ENGINEERING MECHANICS 2018 PROCEEDINGS, VOL 24, 2018, : 69 - 72
  • [4] PRESSURE LOSSES ANALYSIS IN TWO HIGH-PRESSURE STEAM TURBINE CONTROL VALVES SITUATED IN ONE VALVE CHAMBER
    Slama, Vaclav
    Rudas, Bartolomej
    Simurda, David
    Hala, Jindrich
    Luxa, Martin
    PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 2, 2022,
  • [5] INTERACTION OF STEAM-GENERATOR AND TURBINE IN FREQUENCY OUTPUT CONTROL
    PERYCZ, S
    ENERGIETECHNIK, 1978, 28 (04): : 149 - 153
  • [6] INFLUENCE OF OUTPUT VARIATIONS OF HYDRAULIC TURBINE AND GENERATOR ON STABILITY AND QUALITY OF FREQUENCY REGULATION
    SIERVO, FD
    ELETTROTECNICA, 1974, 61 (07): : 653 - 653
  • [7] Flow Analysis in a Steam Turbine Control Valve With Through-Flow Valve Chamber
    Slama, Vaclav
    Mrozek, Lukas
    Tajc, Ladislav
    Klimko, Marek
    Zitek, Pavel
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2021, 7 (02):
  • [8] ANALYSIS OF FLOW FIELDS IN A STEAM TURBINE CONTROL VALVE WITH ONE CHAMBER
    Slama, Vaclav
    Rudas, Bartolomej
    PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 9, 2024,
  • [9] PRESSURE LOSS ANALYSIS IN THE STEAM TURBINE CONTROL VALVE
    Bednar, L.
    Tajc, L.
    Miczan, M.
    Hoznedl, M.
    ENGINEERING MECHANICS 2019, 2019, 25 : 45 - 48
  • [10] Pressure Losses Downstream of a Compact Valve in the Inlet Chamber of an Intermediate-Pressure Steam Turbine
    Slama, Vaclav
    Simurda, David
    Lenhard, Richard
    ENERGIES, 2022, 15 (22)