Will water mist improve fire safety?

被引:0
|
作者
Scott, D. [1 ]
Pankahnia, N. [1 ]
机构
[1] Siemens Building Technologies, Cerberus Division, United Kingdom
来源
World Tunnelling | 2001年 / 14卷 / 08期
关键词
Carbon dioxide - Fog - Safety devices - Scrubbers - Smoke - Ventilation;
D O I
暂无
中图分类号
学科分类号
摘要
A research project aimed at establishing clear guidelines for the management of tunnel fires is currently under way. Using the unique Hagerbach test tunnel facility operated by Siemens Cerberus in Switzerland, the effects of water mist on the heat, smoke and carbon dioxide produced in such a fire are being studied. The initial hypothesis for this research was that water mist not only reduces heat from the fire, but also lowers the levels of carbon dioxide and smoke particles as a result of a chemical 'scrubbing' effect. The results obtained indicate that optimising the use of ventilation and water mist may have an important role to play in minimising danger to human life.
引用
下载
收藏
页码:384 / 385
相关论文
共 50 条
  • [1] On the fire intensification of pool fire with water mist
    Liang, Tianshui
    Zhong, Wei
    Yuen, Richard K. K.
    Lo, Siuming
    Liao, Guangxuan
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 994 - 999
  • [2] Study on the effect of mist flux on water mist fire extinguishing
    Liu, Yang
    Fu, Zhixi
    Zheng, Guanghui
    Chen, Peng
    FIRE SAFETY JOURNAL, 2022, 130
  • [3] Water mist fire suppression systems
    Dyer, J.
    Fire Engineers Journal, 1997, 57 (191):
  • [4] Water mist suppression of a turbulent line fire
    White, James P.
    Verma, Salman
    Keller, Elizabeth
    Hao, Ailing
    Trouve, Arnaud
    Marshall, Andre W.
    FIRE SAFETY JOURNAL, 2017, 91 : 705 - 713
  • [5] Fine water mist fire protection system
    McBride, WE
    INDUSTRY APPLICATIONS SOCIETY 48TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2001, : 245 - 252
  • [6] Extinction limit of a pool fire with a water mist
    Kim, MB
    Jang, YJ
    Yoon, MO
    FIRE SAFETY JOURNAL, 1997, 28 (04) : 295 - 306
  • [7] Extinction limit of a pool fire with a water mist
    Korea Inst of Machinery and, Materials, Taejon, Korea, Republic of
    Fire Saf J, 4 (295-306):
  • [8] Fire tests for water mist fire suppression systems in road tunnels
    Leucker, R.
    Leismann, F.
    UNDERGROUND - THE WAY TO THE FUTURE, 2013, : 366 - 375
  • [9] Scaling Study of Tunnel Fire Suppression by Water Mist
    Zhu Wei
    Chen Luyi
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 875 - 879
  • [10] Effects of water mist addition on kerosene pool fire
    Zhou XiaoMeng
    Qin Jun
    Liao GuangXuan
    CHINESE SCIENCE BULLETIN, 2008, 53 (20): : 3240 - 3246