AC- and DC-side disturbance characteristic analysis of MMC

被引:0
|
作者
Qian W. [1 ]
Zhao Y. [1 ]
Xing F. [2 ]
Xu Z. [2 ]
Chen Y. [1 ]
Hu K. [1 ]
Zhou J. [1 ]
机构
[1] Grid Planning and Research Center, Yunnan Power Grid Co., Ltd., Kunming
[2] College of Electrical Engineering, Zhejiang University, Hangzhou
关键词
Disturbance characteristics; Electric converters; Frequency components balance principle; MMC;
D O I
10.16081/j.epae.202007005
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
For avoiding the oscillation instability risk caused by MMC(Modular Multi-level Converter), the AC- and DC-side disturbance characteristics of MMC is deeply researched. Firstly, based on the dynamic characteristics of bridge-arm inductor and sub-module capacitor, the state-space model of MMC is established. Specially, the influence of the DC-side mid-point voltage is considered. Moreover, based on the frequency component balance principle, the frequency components of each variable in MMC under normal situa-tion, AC- and DC-side disturbance situations are analyzed. Meanwhile, the multi-frequency disturbance matrix is derived to describe the relationship among disturbance frequency components of each variable. On the basis, the accuracy of multi-frequency disturbance matrix is verified by time-domain simulation, and the AC- and DC-side port-impedances of MMC are calculated in sub- and super-synchronous frequency range. Finally, the disturbance amplification effect of MMC is further analyzed based on impedance-frequency characteristics. The results indicate that MMC will amplify the disturbance of certain frequencies in sub- and super-synchronous frequency range, and the specific frequency is related to the system parameters. © 2020, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:114 / 120
页数:6
相关论文
共 19 条
  • [1] pp. 4-5, (2017)
  • [2] PEREZ M A, BERNET S, RODRIGUEZ J, Et al., Circuit topo-logies, modeling, control schemes, and applications of modular multilevel converters, IEEE Transactions on Power Elec-tronics, 30, 1, pp. 4-17, (2015)
  • [3] ZHU Lianghe, YUAN Zhichang, SHENG Chao, Et al., Review of frequency support control methods for asynchronous interconnection system based on VSC-HVDC, Electric Power Automation Equipment, 39, 2, pp. 84-92, (2019)
  • [4] YANG Jingang, YUAN Zhichang, LI Shunxin, Et al., Frequency control strategy for large-scale wind farm grid-connection through VSC-HVDC, Electric Power Automation Equipment, 39, 6, pp. 109-114, (2019)
  • [5] ZHANG Jianpo, JIANG Chang, TIAN Xincheng, Design of sub module topologies and their control for modular multilevel converter, Electric Power Automation Equipment, 39, 7, pp. 78-83, (2019)
  • [6] LI Yan, ZOU Changyue, RAO Hong, Et al., Resonance of VSC-HVDC with extreme AC grid, Proceedings of the CSEE, 38, pp. 19-23, (2018)
  • [7] YIN Congqi, XIE Xiaorong, LIU Hui, Et al., Analysis and control of the oscillation phenomenon in VSC-HVDC transmission system, Power System Technology, 42, 4, pp. 1117-1123, (2018)
  • [8] WANG Xiaoyu, YANG Jie, WU Yanan, Et al., Effect analysis of back-to-back flexible HVDC connecting Chongqing and Hubei Power Grid on sub-synchronous oscillation characteristics, Electric Power Automation Equipment, 39, 7, pp. 188-194, (2019)
  • [9] SUN J., Impedance-based stability criterion for grid-connected inverters, IEEE Transactions on Power Electronics, 26, 11, pp. 3075-3078, (2011)
  • [10] MIAO Z X., Impedance-model-based SSR analysis for Type 3 wind generator and series-compensated network, IEEE Tran-sactions on Energy Conversion, 27, 4, pp. 984-991, (2012)