High-precision absolute value measurement of reflection by time domain OCT

被引:0
|
作者
Tanaka M. [1 ]
Shiina T. [1 ]
机构
[1] Graduate School of Science and Engineering, Chiba University, 1-33 Yayoicho, Inage-ku Chiba
关键词
Absolute value measurement; OCT; Optical connector; Optical fiber; Reflection value;
D O I
10.1541/ieejfms.138.198
中图分类号
学科分类号
摘要
Typical reflectometers have their own standards for measurement values, and they cannot evaluate a certain index each other because of lack of common understanding. Recently there is great demand to measure an absolute value of small reflection in optical communication field. We developed a specialized TD-OCT to evaluate an absolute value of reflection. TD type can evaluate the reflection value directly and linearly. The rotating optical path scanner was installed into the specialized TD-OCT to generate the optical path change of 20 mm. We specially arranged the 4-stage amplifier for the sensitivity of 100 dB. As a result, we got its good linearity of the reflection measurement results within the deviation of 3 dB in the range between 10 to 100 dB. © 2018 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:198 / 203
页数:5
相关论文
共 50 条
  • [1] High-Precision Time-Domain Measurement of Quality Factor
    Zhang, Ming
    Llaser, Nicolas
    Rodes, Francis
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (03) : 842 - 844
  • [2] High-precision time domain reactive power measurement in the presence of interharmonics
    Bei ZHANG Guo WEI Jinwei SUN Department of Electrical and Computer EngineeringAuburn UniversityAuburn USA School of Electrical Engineering and AutomationHarbin Institute of TechnologyHarbin China
    JournalofZhejiangUniversity-ScienceC(Computers&Electronics), 2011, 12 (04) : 330 - 337
  • [3] High-precision time domain reactive power measurement in the presence of interharmonics
    Bei Zhang
    Guo Wei
    Jin-wei Sun
    Journal of Zhejiang University SCIENCE C, 2011, 12 : 330 - 337
  • [5] High-precision time domain reactive power measurement in the presence of interharmonics
    Zhang, Bei
    Wei, Guo
    Sun, Jin-wei
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE C-COMPUTERS & ELECTRONICS, 2011, 12 (04): : 330 - 337
  • [6] High-precision measurement of absolute temperatures using thermistors
    Hans, Volker H.
    Proceedings of the Estonian Academy of Sciences: Engineering, 2007, 13 (04): : 379 - 383
  • [7] Design of a High-Precision Time-Domain Comparator
    Li, Juzhe
    Li, Xu
    Liu, Jiahui
    Zhao, Di
    Yan, Wenrui
    Bi, Chengju
    PROCEEDINGS OF 2019 IEEE 13TH INTERNATIONAL CONFERENCE ON ANTI-COUNTERFEITING, SECURITY, AND IDENTIFICATION (IEEE-ASID'2019), 2019, : 239 - 243
  • [8] High-precision absolute distance and vibration measurement with frequency scanned interferometry
    Yang, HJ
    Deibel, J
    Nyberg, S
    Riles, K
    APPLIED OPTICS, 2005, 44 (19) : 3937 - 3944
  • [9] High-precision absolute coordinate measurement using frequency scanned interferometry
    Tian-Xiang, C.
    Hai-Jun, Y.
    Cheng, L.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [10] HIGH-PRECISION ABSOLUTE PRESSURE GAUGE
    SUPRUNYUK, VV
    MEASUREMENT TECHNIQUES USSR, 1991, 34 (05): : 452 - 454