An Approach to Successful Power-line Interference Suppression in ECG Signals

被引:1
|
作者
Dotsinsky I. [1 ]
机构
[1] Institute of Biophysics and Biomedical Engineering Bulgarian Academy of Science Acad, Georgi Bonchev Str. Bl. 105, Sofia
来源
Dotsinsky, Ivan | 1600年 / Institute of Biophysics and Biomedical Engineering卷 / 26期
关键词
ECG signals; Narrow notch filtration; Power line interference suppression; Subtraction procedure;
D O I
10.7546/ijba.2022.26.1.000848
中图分类号
学科分类号
摘要
The ECG signals acquisition is usually corrupted by presence of Power-Line Interference (PLI) induced by the electromagnetic field around us. Many methods for PLI suppression/elimination have been developed over the years. The easy to apply traditional notch filters suppress unacceptably the ECG spectrum around the rated PL frequencies of 50 or 60 Hz and their deviations, which are restricted by the standards within the range of ± 0.5 Hz. The changes are very slow but the current PL frequency has to be continuously checked to allow start and performance of adequate PLI suppression during any ECG recordings including the 24 hours Holter monitoring. According to the proposed approach, the corrupted ECG recording is bi-directional band-pass (BP) filtered. The resulting sinusoidal BP waves differ in amplitude from the PLI but their zero crossing points remain identical. The two out-sample distances located at both ends of each current sinusoidal curve are calculated and aided to the inter-sample distances. The obtained fractal wave period is converted into current PL frequency and used for bi-directional notch filtration with narrow stop-band. The results obtained demonstrate a very successful PLI suppression in ECG signals. The errors committed are within a few µV, except for the edges of the recordings due to the transition processes. © 2021. by the authors. All Rights Reserved.
引用
收藏
页码:83 / 92
页数:9
相关论文
共 50 条
  • [1] FILTERING OF ECG SIGNALS CORRUPTED WITH POWER-LINE INTERFERENCE
    SHWEDYK, E
    CELLER, BG
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 151 - 151
  • [2] Detection and Suppression of Power-Line Interference in Electrocardiogram Signals
    Hu, Y. H.
    Lin, Y. D.
    COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 : 549 - +
  • [3] Power-line interference detection and suppression in ECG signal processing
    Lin, Yue-Der
    Hu, Yu Hen
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) : 354 - 357
  • [4] Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators
    Ivan Dotsinsky
    BioMedical Engineering OnLine, 4
  • [5] Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators
    Dotsinsky, Ivan
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [6] Robust suppression of nonstationary power-line interference in electrocardiogram signals
    Li, Guojun
    Zeng, Xiaopin
    Zhou, Xiaona
    Zhou, Yu
    Liu, Guojin
    Zhou, Xichuan
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (07) : 1151 - 1169
  • [7] A wavelet-based method for power-line interference removal in ECG signals
    de Oliveira B.R.
    Duarte M.A.Q.
    de Abreu C.C.E.
    Filho J.V.
    Research on Biomedical Engineering, 2018, 34 (01) : 73 - 86
  • [8] Digital Filtering Techniques for Power-line Interference Removal from ECG Signals
    Abrar, Muhammad
    Khan, Waleed Elahi
    2018 CONFERENCE ON INFORMATION COMMUNICATIONS TECHNOLOGY AND SOCIETY (ICTAS), 2018,
  • [9] Testing of digital filters for power-line interference removal from ECG signals
    Mihov, Georgy Slavchev
    Badarov, Dimiter Hristov
    2017 XXVI INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS (ET), 2017,
  • [10] Detection of Power-Line Interference in ECG Signals using Frequency-Domain Analysis
    Lehmann, Constanza
    Reinstaedtler, Juergen
    Khawaja, Antoun
    2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 821 - 824