Determination of Ascorbic Acid by Suppressed Chemiluminescence

被引:0
|
作者
Ma, Quan-Li
Jin, Yong-Ping
You, Hong-Tao
Ma, Hui-Min
机构
[1] Center for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100080, China
[2] Res. Div. Environ. Protect. Z., Hangzhou 310007, China
[3] Tobacco Bureau of Beijing, Beijing 100010, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes a method for determining ascorbic acid by the suppression of DTMC-H2O2 chemiluminescence. Various factors affecting the chemiluminescence determination of ascorbic acid were examined. Under the optimal conditions (1.2×10-4 mol· L-1 of DTMC, 5.0×10-5 mol·L-1 of H2O2, and pH 11.4 Na2HPO4-NaOH), the quenching of the chemiluminescent intensity was proportional to the concentration of ascorbic acid in the range of 1.0×10-7 - 8.0×10-6 mol·L-1, and the detection limit was 8.0× 10-8 mol·L-1 (S/N=3). The RSD was 4.6% for 1.0×10-6 mol·L-1 of ascorbic acid (n = 10). The selectivity of this method was high and no masking agent required *. The proposed method has been applied to the determination of ascorbic acid in real samples. The obtained results were in agreement with those by CuSO4-KI titration.
引用
收藏
相关论文
共 50 条
  • [1] Determination of ascorbic acid by suppressed chemiluminescence
    Ma, QL
    Jin, YP
    You, HT
    Ma, HM
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2002, 22 (06) : 888 - 890
  • [2] Determination of ascorbic acid by flow-injection chemiluminescence method
    Yu, J.
    Zhang, C.
    Tan, Y.
    Ge, S.
    Dai, P.
    Zha, Y.
    LUMINESCENCE, 2008, 23 (02) : 107 - 107
  • [3] Determination of ascorbic acid by flow injection chemiluminescence suppression method
    Li, F
    Zhang, WY
    Zhu, GY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (12) : 1523 - 1526
  • [4] Chemiluminescence flow sensor for the determination of ascorbic acid with immobilized reagents
    Zhang, ZJ
    Qin, W
    TALANTA, 1996, 43 (01) : 119 - 124
  • [5] Ascorbic acid as an alternative coreactant for luminol reaction and sensitive chemiluminescence determination of ascorbic acid in soft drinks
    Li, Hong
    Zhou, Yang
    Du, Jianxiu
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2022, 429
  • [6] DETERMINATION OF ASCORBIC-ACID BY FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    ALWARTHAN, AA
    ANALYST, 1993, 118 (06) : 639 - 642
  • [8] Determination of Ascorbic Acid with Novel Rhodanine Ramification by Flow Injection Chemiluminescence
    Wan, Fu wei
    Yu, Jin hua
    Yan, Mei
    Ge, Shen guang
    Zhang, Cong cong
    LUMINESCENCE, 2010, 25 (02) : 99 - 100
  • [9] DETERMINATION OF ASCORBIC ACID BY A FLOW INJECTION CHEMILUMINESCENCE METHOD WITH A NOVEL RHODANINE
    Yu Jinghua
    Zhang Congcong
    Tan Yun
    Ge Sheenguang
    Dai Ping
    Zhu Yuanna
    BIOLUMINESCENCE AND CHEMILUMINESCENCE, 2009, : 277 - 280
  • [10] Direct chemiluminescence determination of ascorbic acid using flow injection analysis
    Agater, IB
    Jewsbury, RA
    ANALYTICA CHIMICA ACTA, 1997, 356 (2-3) : 289 - 294