Harmonic analysis and detection of power system based on double moment wavelet transform

被引:0
|
作者
Kangyou L. [1 ]
Ling Y. [2 ]
Yuhang T. [1 ]
机构
[1] Chongqing University of Arts and Sciences, Chongqing Yongchuan
[2] Chongqing Electric Power Company, Chongqing Yongchuan
关键词
Balance; Harmonic Detection; Harmonic Suppression; Power System; Wavelet Transform;
D O I
10.1504/IJRIS.2017.090048
中图分类号
学科分类号
摘要
The influence of unbalanced installation of single-phase DG unit with harmonic compensation function in three-phase and three-wire public power grid shows that there will be risk for the unbalanced installation to increase the three-phase current of the power grid. In order to overcome this problem, balanced triple-frequency harmonic function is proposed for the purpose of avoiding the increase in three-phase power grid current. In addition, compared with the traditional method, such method is also capable of reducing the rated power of harmonic current compensation. In order to verify the effectiveness of the method proposed, the balance and unbalanced conditions are verified in experiment and the experimental circuit is a simplified system based on actual three-phase three-wire system. In order to avoid the increase in the harmonic current, a balanced third harmonic suppression method is proposed. Finally, performance of the algorithm proposed has been verified through experiment. Copyright © 2017 Inderscience Enterprises Ltd.
引用
收藏
页码:199 / 204
页数:5
相关论文
共 50 条
  • [1] Harmonic analysis system of power network based on wavelet transform
    Li Zhenmei
    Shen Jin
    Li Tianze
    Yang Shulian
    [J]. ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 536 - +
  • [2] A Power System Harmonic Detection Method Based on Fractional Wavelet Transform
    Dou J.
    Yang X.
    Yang X.
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (03): : 872 - 879
  • [3] Harmonic detection method in power system based on empirical wavelet transform
    Wu J.
    Mei F.
    Chen C.
    Pan Y.
    Li T.
    Zheng J.
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (06): : 136 - 143
  • [4] A Wavelet Transform Power Harmonic Detection Method Based on DSP
    Xie Weicheng
    Xie Yi
    Yang Xia
    Li Yuejing
    [J]. PROCEEDINGS OF THE 29TH CHINESE CONTROL CONFERENCE, 2010, : 4267 - 4272
  • [5] Wavelet-transform-based algorithm for harmonic analysis of power system waveforms
    Pham, VL
    Wong, KP
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1999, 146 (03) : 249 - 254
  • [6] POWER SYSTEM HARMONIC DETECTION BASED ON SECOND-ORDER SYNCHROSQUEEZING WAVELET TRANSFORM
    Di Qi
    Wang Wenbo
    Gu Quan
    Qian Long
    Jin Yun-yu
    [J]. INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2018, 38 (04): : 144 - 151
  • [7] Detecting methods of harmonic in power system based on wavelet transform
    Liu Yuan-Yuan
    Li Mao-Jun
    [J]. 2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 228 - +
  • [8] Frequency domain interpolation wavelet transform based algorithm for harmonic analysis of power system
    Du, TJ
    Chen, GJ
    Lei, Y
    [J]. 2004 INTERNATIONAL CONFERENCE ON COMMUNICATION, CIRCUITS, AND SYSTEMS, VOLS 1 AND 2: VOL 1: COMMUNICATION THEORY AND SYSTEMS, 2004, : 742 - 746
  • [9] New methods of power system harmonic analysis based on wavelet transform with multifrequency band
    [J]. Ren, Z., 2000, Chinese Society for Electrical Engineering (20):
  • [10] Detection and Analysis of Short Duration Disturbances in Power System Based on Wavelet Transform
    Huang Weili
    Huang Weijian
    [J]. PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 5, 2008, : 631 - 634