Optimization of electromagnetic flowmeter excitation coil

被引:1
|
作者
Zhang H. [1 ]
Yue S. [1 ]
Zhang Y. [1 ]
Wang H. [1 ]
机构
[1] School of Electrical Engineering and Automation, Tianjin University, Tianjin
来源
Yue, Shihong (shyue1999@tju.edu.cn) | 1953年 / Central South University of Technology卷 / 47期
基金
中国国家自然科学基金;
关键词
Electromagnetic flowmeter; Magnetic field homogeneity; Magnetic field intensity; Optimization of excitation coil; Weighting function;
D O I
10.11817/j.issn.1672-7207.2016.06.018
中图分类号
学科分类号
摘要
Magnetic field induced by different shapes of excitation coil was simulated from the angle of the weighting function, three indicators, the magnetic flux density along the central axis of the distribution of evenness, along the measuring tube axis of the distribution uniformity and the uniformity of the distribution in the whole space were defined to analyse their magnetic field uniformity respectively, and then the optimal coil shape was chosen. And in the situation of the same coil material cost and the same excitation condition, the relationship between EMF induced by different shape coils and the measured liquid velocity and the level of liquid in the pipe was simulated. The results show that the circular coil magnetic field uniformity is the best. The selection of the best shape of the exciting coil has been done based on the measured liquid level in the pipe line in practical application. © 2016, Central South University Press. All right reserved.
引用
收藏
页码:1953 / 1958
页数:5
相关论文
共 19 条
  • [1] Hayt W.H., Buck J.A., Engineering Electromagnetics, pp. 126-139, (2001)
  • [2] Feng C., Ma X., Introduction to Engineering Electromagnetic Field, pp. 1-30, (2000)
  • [3] Cai W., Ma Z., Qu G., Et al., Electromagnetic Flow Meter, (2004)
  • [4] Wei K., Li B., Non-full pipe electromagnetic flowmeter weighting function finite element analysis, Automation Instrumentation, 33, 9, pp. 69-71, (2011)
  • [5] Kong L., Wang Y., Li Y., Et al., Potential electromagnetic flowmeter under two-phase induction simulation study, Journal of Measurement, 34, 4, pp. 339-344, (2013)
  • [6] Wang J., Numerical simulation and verification of weight function of electromagnetic flow meter, Chinese Journal of Scientific Instrument, 30, 1, pp. 132-137, (2009)
  • [7] Zhang X., Calculation and measurement of electromagnetic flowmeters working magnetic field, Journal of Measurement Technology, 9, pp. 4-6, (1990)
  • [8] Xia Y., Xu Z., Electromagnetic flowmeter measurement and numerical computation of laminar flow transport pipeline flow quantity, Proceeding of the Second International Symposium on IEEE, pp. 169-173, (2009)
  • [9] Huang A., Yang S., Calculation and analysis of non-uniform electromagnetic flowmeter magnetic field, Automation Application, 2, pp. 56-58, (2011)
  • [10] Zhang X., Sun X., The design of magnetic field of electromagnetic flow meter, Journal of Measurement Technology, 8, pp. 6-9, (2010)