Feasibility study of dual-source computed tomography high-pitch scan mode in preoperative evaluation of aortic stenosis referred to transcatheter aortic valve implantation

被引:0
|
作者
机构
[1] Peng, Liqing
[2] Yu, Jianqun
[3] Li, Zhenlin
[4] Li, Wanjiang
[5] Cheng, Wei
来源
Yu, Jianqun (cjr.yujianqun@vip.163.com) | 1600年 / West China Hospital, Sichuan Institute of Biomedical Engineering卷 / 33期
关键词
Blood vessels - Diseases - Biomineralization;
D O I
10.7507/1001-5515.20160152
中图分类号
学科分类号
摘要
The purpose of this study was to explore the feasibility of dual-source computed tomography (DSCT) high-pitch scan mode in the preoperative evaluation of severe aortic stenosis (AS) referred to transcatheter aortic valve implantation (TAVI). Thirty patients with severe AS referred for TAVI underwent cervico-femoral artery joint DSCT angiography. Measurement and calculation of contrast, contrast noise ratio (CNR) and noise of aorta and access vessels were performed. The intra- and inter-observer reproducibilities for assessing aortic root and access vessels were evaluated. Evaluation of shape and plagues of aorta and access vessels was performed. The contrast, CNR and noise of aorta and access vessels were 348.2~457.9 HU, 12.2~30.3 HU and 19.1~48.1 HU, respectively. There were good intra- and inter-observer reproducibilities in assessing aortic root and access vessels by DSCT (mean difference: -0.73~0.79 mm, r=0.90~0.98, P © 2016, Editorial Office of Journal of Biomedical Engineering. All right reserved.
引用
收藏
相关论文
共 50 条
  • [1] Low radiation dose with high-pitch dual-source computed tomography angiography before Transcatheter Aortic Valve Implantation
    Alsaileek, A.
    Al-Mallah, M.
    Alharthi, M.
    Omran, A.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 91 - 91
  • [2] Benefits of High-Pitch 128-Slice Dual-Source Computed Tomography for Planning of Transcatheter Aortic Valve Implantation
    Plank, Fabian
    Friedrich, Guy
    Bartel, Thomas
    Mueller, Silvana
    Bonaros, Nikolaos
    Heinz, Anneliese
    Klauser, Andrea
    Cartes-Zumelzu, Fabiola
    Grimm, Michael
    Feuchtner, Gudrun
    [J]. ANNALS OF THORACIC SURGERY, 2012, 94 (06): : 1961 - 1966
  • [3] Feasibility study of using low-kilovoltage, prospective gating, high-pitch, dual-source computed tomography prior to transcatheter aortic valve replacement: analysis of image quality and radiation dose
    Ma, Yanhe
    Fu, Bo
    Yu, Anhong
    Yang, Yapeng
    Rajiah, Prabhakar Shantha
    Zhang, Hong
    [J]. JOURNAL OF THORACIC DISEASE, 2023, 15 (12) : 6848 - 6857
  • [4] Use of High-Pitch Dual-Source Computed Tomography of the Abdomen and Pelvis to Markedly Reduce Scan Time: A Clinical Feasibility Study
    Hardie, Andrew D.
    Mayes, Nicholas
    Boulter, Daniel J.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (03) : 353 - 355
  • [5] Assessment of aortic annulus dimensions for transcatheter aortic valve replacement (TAVR) with high-pitch dual-source CT: Comparison of systolic high-pitch vs. multiphasic data acquisition
    Capilli, Fabio
    Benndorf, Matthias
    Soschynski, Martin
    Hagar, Muhammad Taha
    Kharabish, Ahmed
    Neumann, Franz-Josef
    Pache, Gregor
    Schlett, Christopher L.
    Bamberg, Fabian
    Krauss, Tobias
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [6] Dual-source CT with metal sphere-tube for preoperative evaluation of patients with aortic valve disease treated by transcatheter aortic valve implantation
    Liu, Bin
    Hu, Jian
    Jiang, Yue
    Zhou, Zhongchun
    Liu, Fei
    Liu, Xingrui
    Hou, Huadong
    Sun, Guifang
    [J]. MATERIALS EXPRESS, 2023, 13 (03) : 547 - 552
  • [7] Subvalvular aortic stenosis: Comprehensive cardiac evaluation with dual-source computed tomography
    Stolzmann, Paul
    Scheffel, Hans
    Bettex, Dominique
    Karlo, Christoph
    Frauenfelder, Thomas
    Pretre, Rene
    Marincek, Borut
    Alkadhi, Hatem
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (01): : 240 - U31
  • [8] Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode
    Wuest, W.
    Anders, K.
    Schuhbaeck, A.
    May, M. S.
    Gauss, S.
    Marwan, M.
    Arnold, M.
    Ensminger, S.
    Muschiol, G.
    Daniel, W. G.
    Uder, M.
    Achenbach, S.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (01) : 51 - 58
  • [9] Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode
    W. Wuest
    K. Anders
    A. Schuhbaeck
    M. S. May
    S. Gauss
    M. Marwan
    M. Arnold
    S. Ensminger
    G. Muschiol
    W. G. Daniel
    M. Uder
    S. Achenbach
    [J]. European Radiology, 2012, 22 : 51 - 58
  • [10] Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI)
    Schoenhagen, Paul
    Hausleiter, Joerg
    Achenbach, Stephan
    Desai, Milind Y.
    Tuzcu, E. Murat
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2011, 1 (01) : 44 - 56