Update o. The BIPM comparison BIPM.RI(II)-K1.Ac-225 of activity measurements o. The radionuclide 225Ac to includ. The 2021 result o. The POLATOM (Poland)

被引:0
|
作者
Coulon R. [1 ]
Michotte C. [1 ]
Courte S. [1 ]
Nonis M. [1 ]
Ziemek T. [2 ]
Marganiec-Gałązka J. [2 ]
Lech E. [2 ]
Saganowski P. [2 ]
Czudek M. [2 ]
Listkowska A. [2 ]
机构
[1] Bureau International des Poids et Mesures, Pavillon de Breteuil, 12bis Grande Rue, Sèvres
[2] National Centre for Nuclear Research Radioisotope Centre (POLATOM), Otwock
关键词
9;
D O I
10.1088/0026-1394/60/1A/06001
中图分类号
学科分类号
摘要
Main text Since 2019, 2 laboratories have submitted 2 samples of 225Ac t. The International Reference System (SIR) for activity comparison a. The Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Ac-225. Recently. The POLATOM (Poland) participated i. The comparison and a key comparison reference value (KCRV) has been calculated. Fo. The first time. The degrees of equivalence between each equivalent activity measured i. The SIR have been calculated an. The results are given i. The form of a table. A graphical presentation is also given. To reac. The main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B o. The BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication b. The CCRI, according t. The provisions o. The CIPM Mutual Recognition Arrangement (CIPM MRA). © 2022 BIPM & IOP Publishing Ltd.
引用
收藏
相关论文
共 50 条
  • [1] Update o. The BIPM comparison BIPM.RI(II)-K1.Ra-223 of activity measurements o. The radionuclide 223Ra to includ. The 2021 result o. The POLATOM (Poland)
    Coulon R.
    Michotte C.
    Courte S.
    Nonis M.
    Ziemek T.
    Marganiec-Gałązka J.
    Lech E.
    Saganowski P.
    Tymiński Z.
    Listkowska A.
    Metrologia, 2023, 60 (1 A)
  • [2] Update o. The BIPM comparison BIPM.RI(II)-K1.Y-88 of activity measurements o. The radionuclide 88Y to includ. The 2016 result o. The LNE-LNHB (France) an. The 2019 result o. The BEV (Austria)
    Michotte C.
    Courte S.
    Coulon R.
    Nonis M.
    Judge S.
    Ratel G.
    Maringer F.J.
    Brettner-Messler R.
    Fréchou C.
    Bobin C.
    Metrologia, 2023, 60 (1 A)
  • [3] Final report of the new BIPM comparison BIPM.RI(II)-K1.Ac-225 of activity measurements of the radionuclide 225Ac to include the 2019 result of the PTB (Germany)
    Michotte, C.
    Courte, S.
    Nonis, M.
    Coulon, R.
    Judge, S.
    Kossert, K.
    Naehle, O.
    METROLOGIA, 2021, 58 (1A)
  • [4] Update of the BIPM comparison BIPM.RI(II)-K1.Sr-85 of activity measurements of the radionuclide 85Sr to include the 2009 result of the POLATOM (Poland)
    Michotte, C.
    Ratel, G.
    Courte, S.
    Dziel, T.
    Listkowska, A.
    METROLOGIA, 2015, 52
  • [5] Update of the BIPM comparison BIPM.RI(II)-K1.Ge-68 of activity measurements of the radionuclide 68Ge to include the 2021 result of the NIM (China)
    Michotte, Carine
    Coulon, Romain
    Courte, Sammy
    Gressier, Vincent
    Nonis, Manuel
    Liu, Haoran
    Liang, Juncheng
    Liu, Meiling
    Zhang, Ming
    Metrologia, 2024, 61 (1 A)
  • [6] Update of the BIPM comparison BIPM.RI(II)-K1.Sr-85 of activity measurements of the radionuclide 85Sr to include the 2018 result of the PTB (Germany)
    Michotte, C.
    Courte, S.
    Nonis, M.
    Coulon, R.
    Judge, S.
    Nalhle, O.
    Takacs, M.
    METROLOGIA, 2021, 58 (1A)
  • [7] Update of the BIPM comparison BIPM.RI(II)-K1.F-18 of activity measurements of the radionuclide 18F to include the NPL
    Ratel, G.
    Michotte, C.
    Woods, M. J.
    METROLOGIA, 2003, 40
  • [8] Update of the BIPM comparison BIPM.RI(II)-K1.F-18 of activity measurements of the radionuclide 18F to include the CIEMAT
    Ratel, G.
    Michotte, C.
    Garcia-Torano, E.
    Los Arcos, J-M
    METROLOGIA, 2004, 41
  • [9] Update of the BIPM comparison BIPM.RI( II)-K1.Gd-153 of activity measurements of the radionuclide 153Gd to include the 2020 result of the NIST (United States)
    Michotte, C.
    Courte, S.
    Nonis, M.
    Coulon, R.
    Judge, S.
    Bergeron, D. E.
    Cessna, J. T.
    Fitzgerald, R. P.
    Laureano-Perez, L.
    Pibida, L.
    METROLOGIA, 2021, 58 (1A)
  • [10] Update of the BIPM comparison BIPM.RI(II)-K1.Tl-201 of activity measurements of the radionuclide 201Tl to include the 2011 result of the NIST (United States)
    Michotte C.
    Courte S.
    Nonis M.
    Coulon R.
    Judge S.
    Ratel G.
    Fitzgerald R.
    Pibida L.
    Metrologia, 2022, 59 (1A):