Compacted Conformal Implantable Antenna with Multitasking Capabilities for Ingestible Capsule Endoscope

被引:0
|
作者
Alamgir, Yousaf [1 ]
Mabrouk, Ismail Ben [2 ]
Faisal, Farooq [3 ]
Zada, Muhammad [4 ]
Bashir, Zubair [1 ]
Akram, Adeel [1 ]
Nedil, Mourad [3 ]
Yoo, Hyoungsuk [4 ]
机构
[1] Telecommunication Engineering Department, ACTSENA Research Group, University of Engineering and Technology Taxila, Taxila,47050, Pakistan
[2] Department of Electrical Engineering, Al Ain University of Science and Technology, Abu Dhabi, United Arab Emirates
[3] Department of Electrical Engineering, University of Quebec, Val d'Or,QC,J9P 1S2, Canada
[4] Department of Biomedical Engineering, Hanyang University, Seoul,04763, Korea, Republic of
关键词
Energy transfer;
D O I
暂无
中图分类号
学科分类号
摘要
This study presents a multi-band conformal antenna based endoscopic system for robust biotelemetry communications, which covers five important bands, including the MedRadio (401-406 MHz), Industrial, Scientific, and Medical (ISM) (433.1-434.8 MHz, 868-868.6 MHz, 902-928 MHz), and midfield (1200 MHz) bands. These bands are intended for functions such as biotelemetry, power saving, and wireless power transfer (WPT). The proposed antenna is printed on a flexible material Rogers ULTRALAM with a thickness of only 0.1 mm, which can be easily wrapped around the inner wall of a capsule. Owing to the insertion of the via and open-ended meandered slots in the radiator and in the ground plane, the footprints of the suggested antenna reduce considerably. In the flat form, the antenna is 57-3 in volume, whereas in the wrapped form, it is only 48.98 3 in volume. In a homogeneous muscle phantom, the proposed conformal antenna shows a 27.46% wider bandwidth at 402 MHz,whereas it shows a 13.2% and 5.42% bandwidth at 915 MHz and 1200 MHz, respectively. Furthermore, the specific absorption rate investigation at three resonance frequencies in various implanted locations shows compliance with the IEEE guidelines, thereby guaranteeing human safety. For measurements, a 3D capsule with batteries and circuitry is devised using a 3D printer, and the simulation results are experimentally validated in a box containing minced pork. Finally, the robustness of the communication link is confirmed through the link budget analysis at 1 Mb/s. The conformal design concept, omni-directional radiations, and multi-band functionality with a wider bandwidth in the MedRadio band of the suggested antenna will enhance the diversity of the capsule endoscope and be a good addition to the field of biotelemetry. © 2013 IEEE.
引用
收藏
页码:157617 / 157627
相关论文
共 50 条
  • [1] Compacted Conformal Implantable Antenna With Multitasking Capabilities for Ingestible Capsule Endoscope
    Alamgir, Yousaf
    Mabrouk, Ismail Ben
    Faisal, Farooq
    Zada, Muhammad
    Bashir, Zubair
    Akram, Adeel
    Nedil, Mourad
    Yoo, Hyoungsuk
    IEEE ACCESS, 2020, 8 : 157617 - 157627
  • [2] Design of an Implantable Antenna for Wireless Communication of Ingestible Capsule Endoscope
    Wang, Jingchen
    Lim, Eng Gee
    Leach, Mark
    Wang, Zhao
    Pei, Rui
    Jiang, Zhenzhen
    2019 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP 2019), 2019,
  • [3] An Ultrawideband Conformal Loop Antenna for Ingestible Capsule Endoscope System
    Suzan, Miah Md
    Haneda, Katsuyuki
    Icheln, Clemens
    Khatun, Afroza
    Takizawa, Ken-ichi
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,
  • [4] DESIGN OF AN ANTENNA FOR AN INGESTIBLE CAPSULE ENDOSCOPE SYSTEM
    Kwon, Kyeol
    Seo, Wonbum
    Lee, Soonyong
    Choi, Jaehoon
    PROCEEDINGS OF THE 3RD IEEE INTERNATIONAL CONFERENCE ON NETWORK INFRASTRUCTURE AND DIGITAL CONTENT (IEEE IC-NIDC 2012), 2012, : 62 - 65
  • [5] Compacted conformal antenna at lower-UWB for wireless capsule endoscope system
    Janapala D.K.
    Moses N.
    Orugu R.
    Journal of Ambient Intelligence and Humanized Computing, 2023, 14 (09) : 12617 - 12633
  • [6] Robust Ultraminiature Capsule Antenna for Ingestible and Implantable Applications
    Nikolayev, Denys
    Zhadobov, Maxim
    Le Coq, Laurent
    Karban, Pavel
    Sauleau, Ronan
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2017, 65 (11) : 6107 - 6119
  • [7] Conformal MIMO loop antenna for ingestible capsule applications
    Xu, Li-Jie
    Li, Bo
    Zhang, Ming
    Bo, Yaming
    ELECTRONICS LETTERS, 2017, 53 (23) : 1506 - 1507
  • [8] A Conformal Differentially Fed Antenna for Ingestible Capsule System
    Zhang, Ke
    Liu, Changrong
    Liu, Xueguan
    Cao, Honglong
    Zhang, Yudi
    Yang, Xinmi
    Guo, Huiping
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2018, 66 (04) : 1695 - 1703
  • [9] Design of a Biomedical Antenna System for Wireless Communication of Ingestible Capsule Endoscope
    Gao, Rushi
    Sun, Hucheng
    Ren, Rui
    Zhang, Haipeng
    IEEE Antennas and Wireless Propagation Letters, 2024, 23 (12): : 4243 - 4247
  • [10] Conformal Ingestible Capsule Antenna: A Novel Chandelier Meandered Design
    Izdebski, Phillip M.
    Rajagopalan, Harish
    Rahmat-Samii, Yahya
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2009, 57 (04) : 900 - 909