Common mode voltage elimination for open winding brushless doubly-fed generator based on direct power control

被引:0
|
作者
Jin S. [1 ]
Wang Z.-Z. [1 ]
Zhang Y. [2 ]
Zhu L.-C. [1 ,3 ]
机构
[1] School of Electrical Engineering, Shenyang University of Technology, Shenyang
[2] School of Electronics, Electrical Engineering and Computer Science, Queen's University Belfast, Belfast
[3] School of Electronic and Information Engineering, University of Science and Technology, Anshan
来源
Jin, Shi | 2018年 / Editorial Department of Electric Machines and Control卷 / 22期
关键词
BDFG; Common DC-bus; Common-mode voltage elimination; Direct power control; Open-winding;
D O I
10.15938/j.emc.2018.02.004
中图分类号
学科分类号
摘要
Brushless doubly-fed generator (BDFG) has two sets of different number windings on the stator, the power winding and control winding, and adopts the hybrid rotor structure consisting of magnetic barrier and cage. Open winding brushless doubly-fed generator (OW-BDFG) opens the control winding entirely and connects a converter to each end. When the two converters use a common DC-bus, the system forms a zero sequence current loop and produces the zero sequence current which affects the efficiency and performance of the system under the action of common-mode voltage. A voltage modulation method was proposed to eliminate common-mode voltage based on direct power control (DPC) for the special structure, both to achieve the decoupling control of active power and reactive power, and to solve the zero sequence current problems existing in the common DC-bus OW-BDFG system. Finally, the effectiveness and superiority of proposed common-mode voltage elimination for open winding brushless doubly-fed generator based on direct power control(CMVE-DPC) method is verified through the simulation and experiment research and comparison analysis. © 2018, Harbin University of Science and Technology Publication. All right reserved.
引用
收藏
页码:24 / 32
页数:8
相关论文
共 12 条
  • [1] Wang X., Liu Y., Jiang N., Et al., Development of wind power technology, Electrical Switch, 51, 3, (2013)
  • [2] Wei C., Talking about the present situation and trend of wind power generation technology, Science and Technology Innovation and Application, 23, (2012)
  • [3] Diao T., Wang X., Permanent power induction motor direct power control, Electric Machines and Control, 17, 4, (2013)
  • [4] Ma H., Xu L., Li Y., Method of grid-connected wind power system based on direct virtual power control, Proceedings of the CSEE, 33, 3, (2013)
  • [5] Pankratov V.V., Kotin D.A., Vdovin V.V., A doubly fed induction motor drive of a mine hoisting plant, Russian Electrical Engineering, 85, 12, (2014)
  • [6] Kalaiselvi J., Sekhar K.R.C., Srinivas S., Common mode voltage elimination PWMs for a dual two-level VSI with single inverter switching, IEEE International Symposium onIndustrial Electronics, (2012)
  • [7] Sekhar K.R., Srinivas S., Current ripple analysis for an asymmetric dual two-level inverter drive with reduced common mode voltage pwm technique, IEEE International Conference on Power Electronics, (2012)
  • [8] Srinivas S., Somasekhar V.T., Switching algorithms for the dual inverter fed open-end winding induction motor drive for 3-level voltage space phasor generation, Asian Power Electronics Journal, 1, 1, (2007)
  • [9] Wang Y., Panda D., Lipo T., Et al., Open-winding power conversion systems fed by half-controlled converters, IEEE Transactions on Power Electronics, 28, 5, (2013)
  • [10] Kalaiselvi J., Sekhar K.R.C., Srinivas S., Common mode voltage elimination PWMs for a dual two-level VSI with single inverter switching, IEEE International Symposium on Industrial Electronics, (2012)