Experimental study on bond behavior for ribbed steel bars and grout

被引:0
|
作者
Yu Q. [1 ]
Xu X. [1 ]
You G. [1 ]
机构
[1] Research Institute of Structural Engineering and Disaster Reduction, Tongji University, Shanghai
来源
Yu, Qiong (yiongyu2005@163.com) | 1600年 / Harbin Institute of Technology卷 / 49期
关键词
Anchorage length; Grout; Ribbed steel bar; Slip surface; Splitting failure; Typical bond-slip curve;
D O I
10.11918/j.issn.0367-6234.201701088
中图分类号
学科分类号
摘要
To provide theoretical data for the grout used in prefabricated structures and reinforcement reconstruction field. Pull-out tests were conducted on 27 specimens having grout with ribbed reinforced bars, and the failure mode and the variation of bond strength were studied. According to a typical bond-slip curve, the cracking, crushing and shearing process were analyzed. Based on the experimental data, the bond strength formula, the slip formula and the bond-slip formula were fitted. The empirical value of anchorage length of reinforcement in grout was presented. The result shows that the average bond strength increases with the increase of the cover thickness. While thickening the cover thickness, the increasing rate of bond strength is lower than that of concrete. In addition, increasing the bar diameter, the average bond strength decreases. Further-more, with the increase of the anchorage length, average bond strength decreases. The increase of anchorage length results in higher increment rate of the bond strength of grout compared to the self-compacting concrete. With the same compressive strength grade, the bond strength of grout is higher than that of ordinary concrete. In conclusion, the bond-slip behavior between ribbed steel bar and grout is different from that of concrete. © 2017, Editorial Board of Journal of Harbin Institute of Technology. All right reserved.
引用
收藏
页码:91 / 101
页数:10
相关论文
共 21 条
  • [1] Wang J., Zhou J., Tang L., Et al., Experimental study on bond-slip relationship between rebar and grouting material, Industrial Construction, 46, pp. 627-630, (2016)
  • [2] Plowman J.M., The measurement of bond strength, RILEM Symposium, 5, pp. 45-66, (1957)
  • [3] Zuo J., Darwin D., Bond strength of high relative rib area reinforcing bars, Structural Engineering and Engineering Materials SM Report, 96, 46, pp. 630-641, (1998)
  • [4] Yerlici V.A., Ozturan T., Factors affecting anchorage bond strength in high-performance concrete, ACI Structural Journal, 97, 3, pp. 499-507, (2000)
  • [5] Kheder G.F., Bond behavior for normal and high strength concrete, Journal of Engineering and Development, 1, 4, pp. 99-119, (2005)
  • [6] Zhang H., Experimental study on plug-in filling hole for lap-joint of steel bar of PC concrete structure, (2009)
  • [7] The State Bureau of Quality and Technical Supervision: Method of testing cements-determination: GB/T 17671-1999, (1999)
  • [8] Standard for test method of mechanical properties on ordinary concrete: GB/T 50081-2002, (2002)
  • [9] Xu Y., Shen W., Wang H., An Experimental study of bond-anchorage properties of bars in concrete, Journal of Building Structures, 15, 3, pp. 26-33, (1994)