Verification of COSINE Reflooding Model and Sensitivity Analysis of Parameters

被引:0
|
作者
Li X. [1 ]
Zhang H. [1 ]
Yang Y. [1 ]
机构
[1] School of Nuclear Science and Engineering, Shanghai Jiaotong University, Shanghai
来源
关键词
COSINE; LOFT experiment; Reflooding; Sensitivity analysis;
D O I
10.13832/j.jnpe.2022.06.0073
中图分类号
学科分类号
摘要
Reflooding is an important stage after the PWR large break accident. In order to evaluate the calculation capability of the system program at this stage, it is necessary to select a variety of heat transfer models to reproduce the accident and analyze the sensitivity response of the parameters. In this paper, the PWR Loss of Fluid Test (LOFT) bench is modeled, and the calculation results of different heat transfer models in the COSINE program are compared with the experimental data to verify the accuracy of the model; At the same time, the parameter sensitivity calculation in the reflooding stage is carried out, and the parameters which have the greatest influence on the second peak cladding temperature (PCT) are identified. The calculation shows that the heat transfer model of COSINE program can well predict the reflooding phenomenon, and the sensitivity parameters that have great influence on the calculation results include UO2 volume heat capacity, droplet diameter, droplet interphase heat transfer coefficient and heat transfer coefficient of film boiling wall against vapor phase. © 2022 Yuan Zi Neng Chuban She. All rights reserved.
引用
收藏
页码:73 / 78
页数:5
相关论文
共 15 条
  • [1] (2002)
  • [2] 35, pp. 166-169, (2014)
  • [3] (2009)
  • [4] (2015)
  • [5] 38, 7, pp. 39-44, (2016)
  • [6] PRASSINOS P G, GALUSHA B M, ENGELMAN D B., Experiment data report for LOFT power ascension experiment L2-3: DE-AC07-76ID01570, (1979)
  • [7] BROMLEY L A., Heat transfer in stable film boiling: AECD-2295, (1948)
  • [8] BERENSON P J., Film-boiling heat transfer from a horizontal surface, Journal of Heat Transfer, 83, 3, pp. 351-356, (1961)
  • [9] DOUGALL R S, ROHSENOW W M., Film boiling of the inside of vertical tubes with upward flow of the fluid at low qualities: Report No. 9079-26, (1963)
  • [10] GROENEVELD D C, MOECK E O., An investigation of heat transfer in the liquid deficient regime: AECL-3281, (1969)