Optimal Design of Highly Uniform Magnetic Field Coils Under High-Permeability Magnetic Shields in Miniaturized NMR Sensors

被引:0
|
作者
Jie, Shaofeng [1 ,2 ]
Liu, Zhanchao [1 ,2 ]
Zhang, Shuai [1 ,2 ]
Wang, Jingsong [1 ,2 ]
Wu, Zekun [3 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100191, Peoples R China
[2] Hefei Natl Lab, Hefei 230026, Peoples R China
[3] Hangzhou Inst Extremely Weak Magnet Field Major Na, Hangzhou 310051, Peoples R China
关键词
Coils; Magnetic fields; Magnetic shielding; Magnetic noise; Sensors; Magnetic sensors; Nuclear magnetic resonance; Magnetic resonance imaging; Magnetic field measurement; Couplings; Genetic algorithm; magnetic coupling effect; nuclear magnetic resonance (NMR) sensors; permalloy magnetic shield; uniform magnetic field coils;
D O I
10.1109/TIM.2024.3472769
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic coils in the magnetic shield are combined to generate a precise and uniform magnetic field for nuclear magnetic resonance (NMR) sensors and shield against the disturbance of the external magnetic field. However, the effect of magnetic shields made of high-permeability materials on coil constants and magnetic field uniformity has become a significant issue for miniaturized NMR sensors. We proposed a novel optimal design method for the magnetic field coils based on the modified Green function of the ferromagnetic boundary and introduced an improved genetic algorithm (IGA) to improve the optimal efficiency. First, the coupling effect of the radius and height of the coil and the magnetic shield was analyzed. Then, a solenoid coil system in the cylindrical magnetic shield was designed and fabricated. In the experiment, compared with the traditional method, the coupling coefficient of the coil constant of the coil designed by the proposed method was reduced of 10.45%. The maximum magnetic field error in the target region reached a significant reduction by two orders of magnitude in calculations and experiments. Moreover, the optimized coils applied to the NMR sensor enhanced the transverse nuclear spin relaxation time of 129Xe by 44.32%, which has the potential to improve the sensor performance.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Hybrid Optimal Design of Square Highly Uniform Magnetic Field Coils
    Lu, Jixi
    Wang, Shuying
    Lu, Fei
    Lu, Chenning
    Zhang, Xu
    Ma, Danyue
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (04) : 4236 - 4244
  • [2] Design of Highly Uniform Three Dimensional Spherical Magnetic Field Coils for Atomic Sensors
    Pang, Haoying
    Duan, Lihong
    Quan, Wei
    Wang, Jing
    Wu, Wenfeng
    Fan, Wenfeng
    Liu, Feng
    IEEE SENSORS JOURNAL, 2020, 20 (19) : 11229 - 11236
  • [3] Calculation of magnetic field noise from high-permeability magnetic shields and conducting objects with simple geometry
    Lee, S. -K.
    Romalis, M. V.
    JOURNAL OF APPLIED PHYSICS, 2008, 103 (08)
  • [4] Calculation of magnetic field noise from high-permeability magnetic shields and conducting objects with simple geometry
    Physics Department, Princeton University, Princeton, NJ 08544, United States
    Journal of Applied Physics, 2008, 103 (08):
  • [5] Hybrid Optimal Design of Biplanar Coils With Uniform Magnetic Field or Field Gradient
    Wang, Jing
    Song, Xinda
    Zhou, Weiyong
    Le, Yun
    Ning, Xiaolin
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (11) : 11544 - 11553
  • [6] Design of Highly Uniform Magnetic Field Coils With Wolf Pack Algorithm
    Xu, Jun
    Kang, Xiangyu
    Fan, Zhengkun
    Zhang, Zhanfei
    Li, Yang
    Dong, Xiangmei
    Gao, Xiumin
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4412 - 4424
  • [7] Design of Highly Uniform Field Coils Based on the Magnetic Field Coupling Model and Improved PSO Algorithm in Atomic Sensors
    Pang, Haoying
    Fan, Wenfeng
    Liu, Feng
    Duan, Lihong
    Liu, Sixun
    Wang, Jing
    Quan, Wei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [8] Design of Highly Uniform Magnetic Field Cylinder Coils Based on Grey Wolf Optimizer Algorithm in Atomic Sensors
    Cao, Qian
    Liu, Ying
    Zhao, Tian
    Yang, Ke
    Tang, Chencheng
    Tao, Runxia
    Hu, Dong
    Zhai, Yueyang
    IEEE SENSORS JOURNAL, 2021, 21 (18) : 19922 - 19929
  • [9] Hybrid optimal design method for magnetic field coils under magnetic shielding boundary
    Wu, Zhihong
    Pang, Haoying
    Wang, Zhuo
    Fan, Wenfeng
    Liu, Feng
    Pei, Hongyu
    Quan, Wei
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 359
  • [10] High-permeability core coils for transcranial magnetic stimulation of deep brain regions
    Salvador, R.
    Miranda, P. C.
    Roth, Y.
    Zangen, A.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 6653 - +