A novel control system of 230kA DC power source with thyristor, phase-shifting rectifier transformer and on-load tap changer

被引:0
|
作者
Department of Electrical Engineering, Shanghai Jiao Tong University, No.800, Dongchuan Road, Minhang District, Shanghai 200240, China [1 ]
不详 [2 ]
机构
来源
WSEAS Trans. Circuits Syst. | 2007年 / 3卷 / 336-341期
关键词
Control system synthesis;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:336 / 341
相关论文
共 16 条
  • [1] A novel control scheme of 230kA DC power source using thyristor, Phase-shifting rectifier transformer and On-load tap changer
    Qiao Shutong
    Jiang Jianguo
    Zuo Dongsheng
    Wu Xiaojie
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 468 - +
  • [2] Design and development of vibration test system for power transformer on-load tap changer
    Xu, Chenbo
    Wang, Fenghua
    Fu, Jian
    Lin, Jiayang
    Jin, Zhijian
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2013, 34 (05): : 987 - 993
  • [3] Study on the condition of reverse control action of tap changer in a single on-load tap changer power system
    Yorino, Naoto, 1600, Scripta Technica Inc, New York, NY, United States (114):
  • [4] A New Maximum Step Voltage Calculation Method of On-Load Tap-Changer for Symmetrical Two-Core Phase-Shifting Transformer
    Liang, Guishu
    Wang, Litong
    Gao, Fei
    Liu, Xin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (06) : 2718 - 2725
  • [5] A STUDY ON THE CONDITION OF REVERSE CONTROL ACTION OF TAP CHANGER IN A SINGLE ON-LOAD TAP CHANGER POWER-SYSTEM
    YORINO, N
    FUNAHASHI, A
    SASAKI, H
    KUBOKAWA, J
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (07) : 44 - 55
  • [6] A novel control technique for on-load tap changer to enlarge the reactive power capability of wind power plants
    Hoseinzadeh, Bakhtyar
    Blaabjerg, Frede
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (14) : 2928 - 2938
  • [7] Study on the Maximum Step Voltage Calculation Method of On-load Tap Changer in Symmetrical Two-core Phase Shifting Transformer
    Gao F.
    Liu X.
    Wang L.
    Li B.
    Zhao X.
    Liang G.
    Li J.
    Guo R.
    Yu X.
    2017, Chinese Society for Electrical Engineering (37): : 2110 - 2119
  • [8] Innovative power flow regulating tap-changer control installed on multiple phase-shifting transformers
    Thompson, Michael J.
    Miller, Hank
    Burger, John
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1637 - 1645
  • [9] Coordinated voltage control of a decoupled three-phase on-load tap changer transformer and photovoltaic inverters for managing unbalanced networks
    Hu, Junjie
    Marinelli, Mattia
    Coppo, Massimiliano
    Zecchino, Antonio
    Bindner, Henrik W.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 131 : 264 - 274
  • [10] Operation Method of On-Load Tap Changer on Main Transformer Considering Reverse Power Flow in Distribution System Connected with High Penetration on Photovoltaic System
    Yoon, Kwang-Hoon
    Shin, Joong-Woo
    Nam, Tea-Yang
    Kim, Jae-Chul
    Moon, Won-Sik
    ENERGIES, 2022, 15 (17)