Contamination properties of long rod porcelain insulator for transmission line

被引:0
|
作者
Gao, Song [1 ]
Liu, Yang [1 ]
Zhang, Baiqing [2 ]
Cui, Yandong [2 ]
Zhao, Chenlong [3 ]
Huang, Yangjue [4 ]
机构
[1] Jiangsu Electrical Power Research Institute, Nanjing,211103, China
[2] Jiangsu Electrical Power Company Maintenance Branch, Nanjing,211102, China
[3] Graduate School at Shenzhen, Tsinghua University, Shenzhen,518055, China
[4] Guangdong Electric Power Company Research Institute, Guangzhou,510600, China
来源
关键词
Artificial pollution test - Ceramic insulator strings - Contamination flashover voltages - Creepage distance effective coefficient - Equivalent salt deposit density - Porcelain insulators - Potential distributions - Three-dimensional finite element method;
D O I
10.13336/j.1003-6520.hve.2014.11.012
中图分类号
学科分类号
摘要
引用
收藏
页码:3381 / 3387
相关论文
共 50 条
  • [1] Study on operating properties of ceramic long rod insulator for transmission line
    Gao, S.
    Liu, Y.
    Zhu, M. X.
    Tao, F. B.
    Zhou, Z. C.
    Bo, B.
    Huang, Y. J.
    MATERIALS RESEARCH INNOVATIONS, 2015, 19 : 70 - 75
  • [2] Investigation of contamination flashover voltage of a porcelain long rod insulator with silicone rubber coating on the trunks
    Gautam, Basanta Kumar
    Matsumura, Shigeki
    Matsushita, Shouta
    Hashimoto, Takuma
    Sakanishi, Kenji
    Matsuoka, Ryosuke
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 591 - +
  • [3] Voltage and Electric Field Distribution along Porcelain Long Rod Insulator String in AC 500kV Transmission Line
    Zhang, Baiqing
    Cui, Yandong
    Zhang, Wei
    Liu, Siyi
    Zheng, Qiuwei
    Yang, Shuai
    Gao, Song
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [4] Research on Detection of Transmission Line Porcelain Insulator Based on Infrared Technology
    Tong, Jie
    Xiao, Zhigen
    Gao, Qiang
    Wang, Yang
    ADVANCED DEVELOPMENT OF ENGINEERING SCIENCE IV, 2014, 1046 : 200 - 204
  • [5] STUDY ON FRACTURE CAUSE OF PORCELAIN INSULATOR OF 220KV TRANSMISSION LINE
    Shen, Hao
    Jia, Ran
    Liu, Rong
    Liu, Hui
    Shen, Qinghe
    IET Conference Proceedings, 2022, 2022 (05): : 1284 - 1289
  • [6] Study on Charged Detection Method of Porcelain Insulator in Single Asymmetric Transmission Line
    Wang, Keqiang
    Tang, Xiaoning
    Shen, Tuo
    Liu, Zhu
    Zhang, Guangxin
    2019 INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA), 2019, : 41 - 45
  • [7] Contamination characteristics of disc-suspension insulator of transmission line in wind tunnel
    Zhang, Zhijin
    You, Jinwei
    Zhao, Jiayao
    Cheng, Yang
    Jiang, Xingliang
    Li, Yongfu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (06) : 1453 - 1460
  • [8] Discrimination of Transmission Line Insulator Contamination Grades using Visible Light Images
    Tian, Zhiren
    Jin, Lijun
    Peng, Chenyi
    Duan, Wei
    Gao, Kai
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [9] New ways for solving the problems connected with porcelain insulator contamination
    Liebermann, J.
    Ogneupory i Tekhnicheskaya Keramika, 2002, (02): : 15 - 25
  • [10] Wind tunnel test for contamination deposited characteristics of porcelain long rod insulators under sandstorm circumstance
    Yang, Lin
    Hao, Yan-Peng
    Li, Li-Cheng
    Zhao, Yu-Ming
    Li, Xiao-Lin
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (11): : 2651 - 2656