Characteristics of natural pollution accumulation of XWP2-70 insulators with double sheds

被引:0
|
作者
Zhang, Zhijin [1 ]
Li, Xing [1 ]
Shu, Shengqian [2 ]
Zhang, Dongdong [1 ]
Jiang, Xingliang [1 ]
机构
[1] State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing,400030, China
[2] Yunnan Electric Power Design Institute, Kunming,650051, China
来源
关键词
Pollution;
D O I
10.13336/j.1003-6520.hve.2014.11.005
中图分类号
学科分类号
摘要
The movement of pollution particles around insulator will cause the pollution deposit on insulator surface. Commonly the atmosphere particle size is 0.1~100 μm, while the size of haze particles is less than 10 μm. We adopted the software of FLUENT to simulate the characteristics of the air flow field of XWP2-70 insulators with double sheds, and studied the pollution particle collision coefficient of insulator surface under different particle diameters and wind velocities. At the same time, we carried out a natural pollution accumulation test which lasted for 8 months in the natural pollution deposition basement. Test results indicate that wind velocity affects air flow field near the surface of insulator, and the collision coefficient P of pollution particles of insulators is affected by haze particle diameters and wind velocity. The obtained results can provide references for establishing pollution deposition model under haze conditions, which is of great significance for the external insulation design and selection of transmission lines. ©, 2014, Science Press. All right reserved.
引用
收藏
页码:3327 / 3335
相关论文
共 16 条
  • [1] Pollution accumulation characteristics of insulators under natural rainfall
    Jiang, Zidan
    Jiang, Xingliang
    Guo, Yujun
    Hu, Yuyao
    Meng, Zhigao
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (06) : 1479 - 1485
  • [2] Study on Pollution Accumulation Characteristics of Typical Insulators
    Gu, Chunhui
    Li, Jiangtao
    Li, Tao
    TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [3] Pollution flashover characteristics of composite insulators installed extra large sheds
    Mei, Hong-Wei
    Chen, Jin-Jun
    Peng, Gong-Mao
    Li, Jian
    Wang, Li-Ming
    Guan, Zhi-Cheng
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (03): : 606 - 612
  • [4] Analysis of Natural Pollution Accumulation Characteristics of Insulators for Railroads in High-Altitude Environment
    Zhang, Zhijin
    Chen, Siyi
    Jiang, Xingliang
    Hu, Jianlin
    Hu, Qin
    ENERGIES, 2023, 16 (15)
  • [5] 可溶物成分对XWP2-70绝缘子串污闪特性的影响
    袁超
    唐梦颖
    赵凯强
    严鹏志
    刘全
    高压电器, 2016, 52 (03) : 118 - 122
  • [6] Natural Pollution Accumulation Characteristics of Composite Insulators for Overhead Transmission Lines in Hunan Power Grid
    Chao Y.
    Gao J.
    Yue Y.
    Wang F.
    Wang C.
    Huang F.
    Chao, Yafeng (yfchao5335@163.com), 2018, Science Press (44): : 2799 - 2806
  • [7] Comparative Investigation of Pollution Accumulation and Natural Cleaning for Different HV Insulators
    Dimitropoulou, M.
    Pylarinos, D.
    Siderakis, K.
    Thalassinakis, E.
    Danikas, M.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2015, 5 (02) : 764 - 774
  • [8] Research on Pollution Accumulation Characteristics of Insulators During Fog-Haze Days
    Xu S.
    Wu C.
    Li S.
    Bao W.
    Liu Y.
    Liang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2017, 37 (07): : 2142 - 2150
  • [9] Analysis of the Pollution Accumulation and Flashover Characteristics of Field aged 110kV Composite Insulators
    Zhang, Zhijin
    Huang, Haizhou
    Jiang, Xingliang
    Chen, Mingying
    Hu, Jianlin
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 120 - 124
  • [10] Simulation study on pollution accumulation characteristics of XP13-160 porcelain suspension disc insulators
    Lv Y.
    Li J.
    Zhang X.
    Pang G.
    Liu Q.