Improving the frosting and defrosting performance of air source heat pump units: review and outlook

被引:0
|
作者
Song M. [1 ]
Dong J. [2 ]
Wu C. [3 ]
Jiang Y. [2 ]
Qu M. [4 ]
机构
[1] School of Materials and Energy, Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, Guangdong University of Technology, Guangzhou
[2] Department of Building Thermal Energy Engineering, Harbin Institute of Technology, Harbin
[3] Building Energy Research Centre, Guangzhou HKUST Fok Ying Tung Research Institute, Guangzhou
[4] School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai
来源
Wu, Chili (chiliwu@ust.hk) | 1600年 / Taylor and Francis Asia Pacific卷 / 24期
基金
中国国家自然科学基金;
关键词
Air source heat pump (ASHP); control strategy; defrosting; frost retardation; multi-circuit outdoor coil;
D O I
10.1080/1023697X.2017.1313134
中图分类号
学科分类号
摘要
When air source heat pump (ASHP) units operate in heating mode at low temperatures in high humidity environments, frost forms and accumulates on the surface of its outdoor coils. This frost layer adversely degrades the operating efficiency of ASHP units rapidly, and can even result in sudden shutdown. Due to this operational problem, many researchers have conducted studies on frost-retardation measures. Since the frost that is present on the ASHP unit after shutdown has to be removed, defrosting becomes necessary. Among several reported defrosting methods, such as compressor shutdown defrosting, electric heating defrosting, hot water spray defrosting and hot gas bypass defrosting, the most popular method is reverse cycle defrosting. In addition, defrosting initiation and termination control play an important role in the frosting and defrosting cycle. Due to a scarcity of reviews of the literature on improving the frosting and defrosting performance of ASHP units, this paper provides a comprehensive review of experimental and modelling studies which explore this topic. This review can be used for guiding the future design and control strategy optimisation for ASHP units. © 2017 The Hong Kong Institution of Engineers.
引用
收藏
页码:88 / 98
页数:10
相关论文
共 50 条
  • [1] Review on improvement for air source heat pump units during frosting and defrosting
    Song Mengjie
    Deng Shiming
    Dang Chaobin
    Mao Ning
    Wang Zhihua
    APPLIED ENERGY, 2018, 211 : 1150 - 1170
  • [2] Review of Anti-frosting and Defrosting Methods on Air Source Heat Pump
    Su, Wei
    Zhang, Xiao-Song
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (09): : 2195 - 2215
  • [3] Developing a new frosting map to guide defrosting control for air-source heat pump units
    Zhu, J. H.
    Sun, Y. Y.
    Wang, W.
    Deng, S. M.
    Ge, Y. J.
    Li, L. T.
    APPLIED THERMAL ENGINEERING, 2015, 90 : 782 - 791
  • [4] PERFORMANCE OF AN AIR-TO-AIR HEAT-PUMP UNDER FROSTING AND DEFROSTING CONDITIONS
    KAYGUSUZ, K
    APPLIED ENERGY, 1994, 48 (03) : 225 - 241
  • [5] Operating characteristics of an air-source heat pump under frosting/defrosting conditions
    He, Z
    Peng, X
    Xing, Z
    Shu, P
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2003, 217 (A6) : 623 - 629
  • [6] Investigation of defrosting water retention on the surface of evaporator impacting the performance of air source heat pump during periodic frosting-defrosting cycles
    Li, L. T.
    Wang, W.
    Sun, Y. Y.
    Feng, Y. C.
    Lu, W. P.
    Zhu, J. H.
    Ge, Y. J.
    APPLIED ENERGY, 2014, 135 : 98 - 107
  • [7] Determination of the defrosting duration ratio for defrosting performance evaluation of air source heat pump
    Li, Zhaoyang
    Wei, Wenzhe
    Wang, Wei
    Sun, Yuying
    Wang, Shiquan
    Tang, Rui
    Lin, Yao
    Huang, Chengyang
    Deng, Shiming
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [8] Experimental investigation on improving defrosting performance of air source heat pump through vapor injection
    Wei, Wenzhe
    Ni, Long
    Dong, Qian
    Wang, Wei
    Ye, Jiayu
    Xu, Laifu
    Yang, Yahua
    Yao, Yang
    Energy and Buildings, 2022, 256
  • [9] Experimental investigation on improving defrosting performance of air source heat pump through vapor injection
    Wei, Wenzhe
    Ni, Long
    Dong, Qian
    Wang, Wei
    Ye, Jiayu
    Xu, Laifu
    Yang, Yahua
    Yao, Yang
    ENERGY AND BUILDINGS, 2022, 256
  • [10] Frosting suppression performance enhancement of air source heat pump through improving relative capacity
    Wei, Wenzhe
    Feng, Zhenglei
    Ni, Long
    Wang, Wei
    Jin, Xinyue
    Tang, Rui
    Zhao, Shunan
    APPLIED THERMAL ENGINEERING, 2024, 236