Research on seismic behavior of cruciform special-shaped CFST column to H-section steel beam joint

被引:0
|
作者
He Z. [1 ,2 ]
Hu S. [1 ,2 ]
Li B. [1 ,2 ,3 ]
Yang Y. [1 ,2 ]
Cheng Y. [1 ,2 ]
机构
[1] Key Laboratory of New Technology for Construction of Cities in Mountain Area, The Ministry of Education, Chongqing University, Chongqing
[2] School of Civil Engineering, Chongqing University, Chongqing
[3] State Key Laboratory for Track Technology of High-Speed Railway, Beijing
关键词
beam to column joint; cross-shaped concrete-filled steel tubular (CFST) column; finite element analysis; quasi-static test; seismic behavior;
D O I
10.14006/j.jzjgxb.2021.0225
中图分类号
学科分类号
摘要
To investigate the seismic behavior and failure mechanism of interior joint between concrete-filled steel tubular (CFST) column and H-section steel beam, quasi-static tests were carried out on six specimens with scale ratio of 1∶ 2. The damage process and failure mode were observed, and the load-displacement hysteretic curves, the joint shear deformation, inter-story drift ratio composition, energy dissipation capacity and strain distribution were analyzed. A finite element (FE) model using ABAQUS software was established and verified with the experimental results. Furthermore, a parametric analysis with the FE model was conducted to investigate the influences on the joint shear capacity and joint stiffness. The results show that the hysteretic curve of the joint is plump. The ductility coefficient is between 2. 63-4. 45. The equivalent viscous damping coefficient is between 0. 202-0. 241. The deformation and energy dissipation capacity of the joint panel zone are relatively favorable. The finite element analysis model can be used to simulate the seismic performance of the joint. Numerical results show that increasing the joint steel tube thickness can significantly improve the shear resistance of the joint panel zone, and increasing the vertical rib dimensions can effectively improve the joint stiffness. To meet the rigid joint requirements of vertical rib joints, it is suggested that the width thickness ratio of column steel plate should not be greater than 30. The outer height of the vertical rib, the inner height, the connection length between the vertical rib and the beam flange should not be less than 30%, 15% and 150% of the beam flange width, respectively. The thickness of the vertical rib should not be less than the thickness of the beam flange. © 2022 Science Press. All rights reserved.
引用
收藏
页码:95 / 106
页数:11
相关论文
共 23 条
  • [1] YAN Shichao, KANG Guyi, WANG Yiqun, Et al., Comprehension and application of technical specification for concrete structures with special-shaped columns, pp. 15-23, (2007)
  • [2] LIU Jiepeng, SONG Hua, YANG Yuanlong, Research on mechanical behavior of L-shaped multi-cell concrete-filled steel tubular stub columns under axial compression [J], Advances in Structural Engineering, 22, 2, pp. 427-443, (2019)
  • [3] YANG Yuanlong, YANG Hua, ZHANG Sumei, Compressive behavior of T-shaped concrete-filled steel tubular columns [ J], International Journal of Steel Strucutres, 10, 4, pp. 419-430, (2010)
  • [4] KUROBANE Y, PACKER J A, WARDENIER J, Et al., Design guide for structural hollow section column connections, pp. 23-33, (2004)
  • [5] SCHNEIDER S P, ALOSTAZl Y M., Experimental behavior connections to concrete-filled steel tubes, Journal of Constructional Steel Research, 45, 3, pp. 321-352, (1998)
  • [6] XU Chengxiang, WU Zanjun, ZENG Lei, Et al., Experimental research on seismic behavior of top corner in composite frame consisting of CFST columns and steel beams [ J ], Journal of Building Structures, 33, 8, pp. 58-65, (2012)
  • [7] XU Chengxiang, WAN Bo, ZHANG Jicheng, Et al., Experimental research on seismic behavior of interior joints in the composite frame consisting of CFST crisscross section columns and steel beams, Building Structure, 42, 3, pp. 80-83, (2012)
  • [8] ZHOU Peng, XUE Jianyang, CHEN Xi, Et al., Experimental study on seismic performance of joints between concrete-filled square steel tubular special-shaped columns and steel beams [J], Journal of Building Sturctures, 33, 8, pp. 44-50, (2012)
  • [9] XUE Jianyang, CHEN Xi, ZHOU Peng, Et al., Shear capacity of joints between concrete-filled square steel tubular special-shaped columns and steel beam [ J ], Journal of Building Sturctures, 33, 8, pp. 51-57, (2012)
  • [10] Lin Mingsen, Seismic behavior of T-shaped concrete-filled steel tubular column and steel beam connections, pp. 30-37, (2012)