Refractive lenses for coherent x-ray sources

被引:0
|
作者
Pantell, Richard H. [1 ]
Feinstein, Joseph [1 ]
Beguiristain, H. Raul [2 ]
Piestrup, Melvin A. [2 ]
Gary, Charles K. [2 ]
Cremer, J. Theodore [2 ]
机构
[1] Department of Electrical Engineering, Stanford University, Stanford, CA 94305, United States
[2] Adelphi Technology Incorporated, 2181 Park Boulevard, Palo Alto, CA 94306, United States
来源
Applied Optics | 2001年 / 40卷 / 28期
关键词
Aberrations - Coherent light - Image analysis - Light emission - Light refraction - Light transmission - Refractive index - X rays;
D O I
暂无
中图分类号
学科分类号
摘要
Incoherent x rays in the wavelength interval from approximately 0.5-2 A have been focused with refractive lenses. A single lens would have a long focal length because the refractive index of any material is close to unity; but with a stack of N lens elements the focal length is reduced by the factor N, and such a lens is termed a compound refractive lens (CRL). Misalignment of the parabolic lens elements does not alter the focusing properties and results in only a small reduction in transmission. Based on the principle of spontaneous emission amplification in a FEL wiggler, coherent x-ray sources are being developed with wavelengths of 1-1.5 A and source diameters of 50-80 μm; and the CRL can be used to provide a small, intense image. Chromatic aberration increases the image size by an amount comparable with the diffraction-limited size, and so chromatic correction is important. Pulse broadening through the lens that is due to material dispersion is negligible. The performance of a CRL used in conjunction with a coherent source is analyzed by means of the Kirchhoff integral. For typical parameters, intensity gain is 105-106, where gain is defined as the intensity ratio in an image plane with and without the lens in place. (There may be some confusion concerning the usage of the word intensity. As employed in this manuscript, intensity, also called irradiance, refers to power per unit area. This is a commonly accepted usage for intensity, although there are places in the literature where the term radiant incidence is reserved for this definition and intensity refers to power per unit solid angle.) The image intensity is maximized when the CRL is placed 100-200 m from the source, and the diameter of the diffraction-limited spot is approximately 0.12 μm. © 2001 Optical Society of America.
引用
收藏
页码:5100 / 5105
相关论文
共 50 条
  • [1] Refractive lenses for coherent x-ray sources
    Pantell, RH
    Feinstein, J
    Beguiristain, HR
    Piestrup, MA
    Gary, CK
    Cremer, JT
    [J]. APPLIED OPTICS, 2001, 40 (28) : 5100 - 5105
  • [2] Compound refractive lenses for novel X-ray sources
    Piestrup, MA
    Beguiristain, HR
    Gary, CK
    Cremer, JT
    Pantell, RH
    Tatchyn, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 173 (1-2): : 170 - 177
  • [3] Refractive x-ray lenses
    Lengeler, B
    Schroer, CG
    Kuhlmann, M
    Benner, B
    Guenzler, TF
    Kurapova, O
    Zontone, F
    Snigirev, A
    Snigireva, I
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (10A) : A218 - A222
  • [4] Parabolic Refractive X-ray Lenses
    Lengeler, Bruno
    Benner, Boris
    Kuhlmann, Marion
    Schroer, Christian
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C20 - C21
  • [5] Parabolic refractive X-ray lenses
    Lengeler, B
    Schroer, CG
    Benner, B
    Gerhardus, A
    Günzler, TF
    Kuhlmann, M
    Meyer, J
    Zimprich, C
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 119 - 124
  • [6] Hard X-ray Nanoprobe with Refractive X-ray Lenses
    Schroer, Christian
    Kurapova, Olga
    Patommel, Jens
    Boye, Pit
    Feldkamp, Jan
    Lengeler, Bruno
    Burghammer, Manfred
    Riekel, Christian
    Vincze, Laszlo
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C64 - C65
  • [7] Hard X-Ray Nanoprobe with Refractive X-Ray Lenses
    Schroer, Christian
    Kurapova, Olga
    Patommel, Jens
    Boye, Pit
    Feldkamp, Jan
    Lengeler, Bruno
    Burghammer, Manfred
    Riekel, Christian
    Vincze, Laszlo
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2006, 62 : S93 - S93
  • [8] Parabolic refractive X-ray lenses:: a breakthrough in X-ray optics
    Lengeler, B
    Schroer, CG
    Benner, B
    Günzler, TF
    Kuhlmann, M
    Tümmler, J
    Simionovici, AS
    Drakopoulos, M
    Snigirev, A
    Snigireva, I
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 944 - 950
  • [9] Hard X-ray nanoprobe based on refractive X-ray lenses
    Schroer, C. G.
    Kurapova, O.
    Patommel, J.
    Boye, P.
    Feldkamp, J.
    Lengeler, B.
    Burghammer, M.
    Riekel, C.
    Vincze, L.
    van der Hart, A.
    Kuechler, M.
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1295 - +
  • [10] Extrusion of compound refractive x-ray lenses
    Young, K
    Khounsary, A