Monitoring and numerical simulation of deep foundation pit of a subway station in Lanzhou

被引:0
|
作者
Ye S.-H. [1 ,2 ,3 ]
Ding S.-H. [1 ,2 ]
Gong X.-N. [3 ]
Gao S. [4 ]
Chen C.-L. [5 ]
机构
[1] Key Laboratory of Disaster Mitigation in Civil Engineering of Gansu Province, Lanzhou University of Technology, Lanzhou
[2] Western Center of Disaster Mitigation in Civil Engineering, Ministry of Education, Lanzhou University of Technology, Lanzhou
[3] Research Center of Coastal and Urban Geotechnical Engineering, Zhejiang University, Hangzhou
[4] China Railway Frist Survey and Design Institute Group Co., Ltd., Xi'an
[5] China Mobile Group Gansu Co., Ltd., Lanzhou
关键词
Axial force of support; Deformation; Foundation pit; Groundwater level; Monitoring analysis; Numericl simulation; Subway station;
D O I
10.11779/CJGE2018S1029
中图分类号
学科分类号
摘要
Based on the foundation pit of a subway station in Lanzhou, the horizontal and vertical displacements of pile top, surface settlement, axial force of steel supports and groundwater level of foundation pit during construction are monitored, and the monitoring data are analyzed. The monitoring results show that the horizontal displacement of pile top gradually changes from small to large and the vertical one of pile top increases with the increase of excavation depth, and the axial force of steel supports in the excavation process tends to be stable. Finally, the finite element software is used to simulate the excavation of the foundation pit. The simulated and monitoring results are compared. The results show that the numerical simulations and the monitoring results basically have the same variation rules. It is proved that the combined structure of steel tube bored pile and support is safe and feasible, and it ensures and maintains the stability of the foundation pit. This study may provide effective and reliable reference for the construction of similar foundation pits. © 2018, Editorial Office of Chinese Journal of Geotechnical Engineering. All right reserved.
引用
收藏
页码:177 / 182
页数:5
相关论文
共 12 条
  • [1] Ye S.-H., Chen C.-L., Kou W.-W., Et al., Displacement monitoring and deformation characteristics of a deep foundation pit in Lanzhou, Chinese Journal of Geotechnical Engineering, 36, pp. 440-445, (2014)
  • [2] Ren Y.-Z., Zhu Y.-P., Zhou Y., Design and monitoring of bracings for a deep foundation pit in Lanzhou, Chinese Journal of Geotechnical Engineering, 36, pp. 705-710, (2014)
  • [3] Zhou Y., Guo N., Zhu Y.-P., Et al., Design and construction monitoring analysis of deep foundation pit support in Lanzhou Metro test section, Journal of Lanzhou University of Technology, 4, pp. 110-114, (2014)
  • [4] Ding Z., Yu X.-F., Wang J.-Y., Et al., Monitoring and analysis of deep foundation pit at Xingtang Road-jingfang Road cross of Hangzhou metro, Chinese Journal of Geotechnical Engineering, 35, pp. 445-451, (2013)
  • [5] Xu Z.-H., Wang W.-D., Deformation control criteria of deep excavatoins, Chinese Joumal of Underground Space and Engineering, 3, pp. 619-626, (2010)
  • [6] Xu Y.-Q., Cheng L., Analysis processing of monitoring data and forecast and early warning system of foundation pits, Chinese Journal of Geotechnical Engineering, 36, pp. 219-224, (2014)
  • [7] JGJ 120-2012 Technical specification for retaining and protection of building foundation excavations, (2012)
  • [8] (2013)
  • [9] JGJ 8-2016 Code for measurement of building deformation, (2016)
  • [10] GB 50026-2007 Code for engineering surveying, (2007)