Harmonic Resonance Damping Method of Photovoltaic Power Station Based on Inductive Filtering

被引:0
|
作者
Li Y. [1 ]
Liu P. [1 ]
Hu S. [1 ]
Lin J. [1 ]
Luo L. [1 ]
机构
[1] College of Electrical and Information Engineering, Hunan University, Changsha
关键词
equivalent model; inductive filtering; Photovoltaic power station; resonance suppression;
D O I
10.19595/j.cnki.1000-6753.tces.211016
中图分类号
学科分类号
摘要
In photovoltaic (PV) power stations, a large number of photovoltaic inverters working under the “weak network” are more likely to motivate harmonic resonance with the power grid, which threatens the power supply continuity and operation safety of the power station. In this paper, based on a real PV substation, the harmonic equivalent model of the traditional PV power station is established which considers the variation of the network impedance of the upstream of the grid, and the resonance is analyzed. On this basis, considering the real harmonic resonance in the traditional PV power station, this paper proposes a harmonic resonance damping method of PV power station based on inductive filtering. The harmonic model and resonance suppression mechanism are analyzed in detail. In this method, the filtering winding of the inductive filtering transformer (IFT) adopts a special zero impedance design, which is externally connected with a fully tuned passive filter (PF). It can obtain better harmonic filtering ability. At the same time, it can effectively eliminate the harmonic resonance of PV power station in the traditional PV power station by changing the impedance frequency characteristics of the whole network of PV power station. Finally, through the simulation and the measured data of the large engineering application, the excellent characteristics of the new method is verified. © 2022 Chinese Machine Press. All rights reserved.
引用
收藏
页码:3781 / 3793
页数:12
相关论文
共 28 条
  • [1] Zhou Xiaoxin, Chen Shuyong, Lu Zongxiang, Et al., Technology features of the new generation power system in China, Proceedings of the CSEE, 38, 7, pp. 1893-1904, (2018)
  • [2] Sun Zhen'ao, Yang Zilong, Wang Yibo, Et al., The cause analysis and suppression method of resonances in clustered grid-connected photovoltaic inverters, Proceedings of the CSEE, 35, 2, pp. 418-425, (2015)
  • [3] Xie Zhiwei, Chen Yandong, Wu Wenhua, Et al., A global high-frequency oscillation suppression method for multi-inverter grid-connected system in weak grid, Transactions of China Electrotechnical Society, 35, 4, pp. 885-895, (2020)
  • [4] Lu Minghui, Yang Yongheng, Johnson B, Et al., An interaction-admittance model for multi-inverter grid-connected systems, IEEE Transactions on Power Electronics, 34, 8, pp. 7542-7557, (2019)
  • [5] Tu Chunming, Gao Jiayuan, Zhao Jinbin, Et al., Analysis and design of grid-connected inverter impedance remodeling with fixed stability margin in weak grid, Transactions of China Electrotechnical Society, 35, 6, pp. 1327-1335, (2020)
  • [6] Shuai Zhikang, Liu Dingguo, Shen J, Et al., Series and parallel resonance problem of wideband frequency harmonic and its elimination strategy, IEEE Transactions on Power Electronics, 29, 4, pp. 1941-1952, (2014)
  • [7] Qian Zhaoming, Ye Zhongming, Dong Bofan, Harmonics suppression techniques, Automation of Electric Power System, 21, 10, pp. 48-54, (1997)
  • [8] Xu Dezhi, Wang Fei, Ruan Yi, Passive damping of LCL, LLCL and LLCCL filters, Proceedings of the CSEE, 35, 18, pp. 4725-4735, (2015)
  • [9] Chen Jie, Zhang Xinying, Yan Zhenyu, Et al., Dead-time effect and background grid-voltage harmonic suppression methods for inverters with virtual impedance control, Transactions of China Electrotechnical Society, 36, 8, pp. 1671-1680, (2021)
  • [10] Fang Tianzhi, Huang Chun, Chen Naiming, Et al., Optimized design of state variable feedback of grid-connected inverter with LCL-filter based on state observer, Transactions of China Electrotechnical Society, 33, 20, pp. 4813-4822, (2018)