Intensity modulated radiotherapy (IMRT) allows dose distributions which adequately consider organs at risk (OAR) and dose homogeneity to the target volume. This is practically reached by conforming the beam profiles to the shape of the planning target volume (PTV), by shaping the fluence with multileaf collimators (MLC) or compensators. Though compensator production is time consuming and seems less convenient than the use of MLC, compensators offer much easier quality assurance. In this study the effects of certain simplifications of compensator production were studied. Compensators were produced and ionization chamber measurements in a water phantom and film measurements in a solid phantom were performed to verify the compensators. The results of the measurements were compared to the fluence distributions given by the planning system. The measurements were meant to show how realistic the investigated simplifications were, and to reveal a suitable and reliable testing method for compensators. Monte-Carlo calculations employing the EGS 4 Code were further performed to support the measurements.
引用
收藏
页码:15 / 22
相关论文
共 50 条
  • [1] Quality assurance of IMRT
    Chui, CS
    LoSasso, T
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 168 - 169
  • [2] Quality of IMRT with compensators in the head and neck region
    Salz, H
    Abbasi, N
    Wiezorek, T
    Scheithauer, M
    Wendt, TG
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 60 - 60
  • [3] IMRT system quality assurance
    Low, D
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1412 - 1412
  • [4] Quality assurance for IMRT and IGRT
    Bissonnette, J-P
    Moseley, D.
    Purdie, T.
    Sharpe, M.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2618 - +
  • [5] A Simple Method for Quality Assurance of Proton Compensators
    Zhao, Q.
    Wu, H.
    Zhao, L.
    Das, I.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Quality assurance of IMRT using EPID
    Vanstraelen, B.
    Verstraete, J.
    Depuydt, T.
    Van den Heuvel, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S190 - S191
  • [7] Quality assurance of IMRT: the QUASIMODO project
    Gillis, S
    De Wagter, C
    Bohsung, J
    Mijnheer, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S46 - S47
  • [8] Quality Assurance for SRS/SRT IMRT
    Guo, F.
    Chen, Z.
    Deng, J.
    Fan, Y.
    Nath, R.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2764 - +
  • [9] Patient quality assurance of IMRT radiation
    Sidow, D.
    Blank, E.
    Buchali, A.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 95 - 95
  • [10] Quality assurance of IMRT planning with EPIDOS
    Weingandt, H.
    Reiner, M.
    Belka, C.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 92 - 92