The power grid integration performance of renewable energy, such as wind power, is more sensitive to grid strength. As an important indicator of the grid strength at the wind farm point of connection, the online identification of grid Thevenin equivalent parameters is significant for stability risk assessment and control strategy optimization of the wind power integrated system. First, the principle of Thevenin equivalent impedance estimation is introduced, and the impacts of both side fluctuations on parameter estimation errors are analyzed. The principle of data screening for equivalent impedance identification and its online application is clarified. Then, a method based on data screening and impedance linear description for equivalent impedance online identification under resource side and grid side fluctuations is proposed, which can effectively overcome the problem of inaccurate equivalent parameters identification under system side fluctuations. Finally, the method is verified by simulation and field cases. © 2024 Power System Technology Press. All rights reserved.
引用
收藏
页码:2376 / 2384
页数:8
相关论文
共 31 条
  • [1] HAN Minxiao, Zhao Zhengkui, ZHENG Jinghong, Development of dynamic voltage support for power grid with large sale renewable energy generation[J], Power System Technology, 47, 4, pp. 1309-1327, (2023)
  • [2] LI Shaolin, WANG Weisheng, ZHANG Xing, Impact of wind power on power system frequency and combined virtual inertia control [J], Automation of Electric Power Systems, 43, 15, pp. 64-70, (2019)
  • [3] CHEN Guoping, LI Mingjie, XU Tao, Practice and challenge of renewable energy development based on interconnected power grids [J], Power System Technology, 41, 10, pp. 3095-3103, (2017)
  • [4] WANG Weisheng, LIN Weifang, HE Guoqing, Enlightenment of 2021 Texas blackout to the renewable energy development in China [J], Proceedings of the CSEE, 41, 12, pp. 4033-4042, (2021)
  • [5] LIANG Jun, LI Chuanyue, Recent development of grid-connected inverters and weak-grid stabilization[J], Power System Technology, 46, 10, pp. 3703-3711, (2022)
  • [6] YI Jun, LIN Weifang, YU Fangfang, Calculation method of critical penetration of renewable energy constrained by static voltage stability[J], Power System Technology, 44, 8, pp. 2906-2912, (2020)
  • [7] Xu Jieyi, Wei LIU, LIU Shu, Current state and development trends of power system converter grid-forming control technology[J], Power System Technology, 46, 9, pp. 3586-3595, (2022)
  • [8] Ming LI, ZHANG Xing, YANG Yang, The grid impedance adaptation dual mode control strategy in weak grid[C], 2018 International Power Electronics Conference (IPEC-Niigata 2018-ECCE Asia), pp. 2973-2979, (2018)
  • [9] YAN Peilei, GE Xinglai, WANG Huimin, PLL parameter optimization design for renewable energy grid-connected inverters in weak grid[J], Power System Technology, 46, 6, pp. 2210-2221, (2022)
  • [10] IEEE.IEEE guide for planning DC links terminating at AC locations having low short-circuit capacities:IEEE 1204—1997[S], (1997)