Seismic response analysis of precast pier with different connection structures

被引:0
|
作者
Hu Z. [1 ]
Yan M. [1 ]
Zhou Z. [1 ]
Wang J. [2 ]
机构
[1] School of Transportation and Logistics Engineering, Wuhan University of Technology, Wuhan
[2] Yellow River Engineering Consulting Co., Ltd., Zhengzhou
关键词
connection structure; finite element simulation; parameter analysis; precast pier; seismic response analysis;
D O I
10.11918/202104092
中图分类号
学科分类号
摘要
To study whether the connection of precast piers can form a reliable force transmission mechanism and its seismic performance, based on a set of quasi-static tests of precast piers, we established finite element models of the test piers by ABAQUS and verified the effectiveness through test results. Then, the seismic dynamic responses of cast-in-place pier, precast pier with grouted corrugated duct connection, and precast pier with tenon-grouted corrugated duct connection were analyzed. Finally, the influence of axial compression ratio and reinforcement ratio on the seismic dynamic response of the precast pier with tenon structure was further studied. Results show that the dynamic responses of precast pier and cast-in-place pier were basically the same under the same structural form and seismic load. The displacement response, residual displacement, and plastic damage of precast pier with tenon were smaller than those with plane joint, and the seismic performance of precast pier with tenon was improved. Through parameter analysis, it was found that with the increase in the axial compression ratio, the displacement response and plastic damage of the pier were larger, and the shear response and seismic energy consumption were greater. With increasing longitudinal reinforcement ratio, the displacement response and plastic damage of the pier decreased, and the shear response increased, while the influence on the seismic energy dissipation was not significant in the range of 1% to 2%. © 2022 Harbin Institute of Technology. All rights reserved.
引用
收藏
页码:55 / 64
页数:9
相关论文
共 18 条
  • [1] HAN Chao, ZHENG Yimin, ZHAO Yong, Research and application development of grout sleeve splicing for reinforcement[J], Construction Technology, 42, 21, (2013)
  • [2] YAN Chang, LIU Duo, ZHANG Jiandong, Research progress and engineering application of precast pier connection structure[C], Proceedings of 2019 Highway Development in the Pan Yangtze River Delta, (2019)
  • [3] SANG Zhongwei, Quasi-static test and numerical analysis of grouted bellows connected assembly piers, (2018)
  • [4] JIANG Haixi, WANG Zhiqiang, SHEN Jiawei, Anti-seismic performance testing of prefabricate assembly pillars connected with grouting metal corrugated pipe, Structural Engineers, 32, 5, (2016)
  • [5] BAO Longsheng, ZHANG Yuanbao, SANG Zhongwei, Et al., Quasi-static test and numerical simulation analysis for seismic performance of fabricated assemble bridge piers base on bellows connection[J], China Journal of Highway and Transport, 31, 12, (2018)
  • [6] TAZARV M, SAIIDI M S., UHPC-filled duct connections for accelerated bridge construction of RC columns in high seismic zones, Engineering Structures, 99, (2015)
  • [7] XIA Zhanghua, YU Zhouyang, GE Jiping, Et al., Bi-axial quasi-static experiment for assembled double-column piers with grouting metal corrugated pipe and prestressed tendons[J], China Journal of Highway and Transport, 34, 1, (2021)
  • [8] WANG Zhiqiang, WEI Zhangzhen, WEI Hongyi, Et al., Influences of precast segmental connector forms on seismic performance of bridge pier[J], China Journal of Highway and Transport, 30, 5, (2017)
  • [9] GE Jiping, XIA Zhanghua, JIANG Heng, Biaxial quasi-static experiment of precast segmental bridge piers with grouting corrugated pipe connection[J], China Journal of Highway and Transport, 31, 12, (2018)
  • [10] HUANG Yi, QIU Wenliang, HUANG Cailiang, Et al., Experimental study of seismic performance of single segmental precast bridge piers [J], Journal of Dalian University of Technology, 56, 5, (2016)