Analysis and application of small disturbance stability sensitivity of photovoltaic accessed system

被引:0
|
作者
Ma Y. [1 ]
Jing X. [1 ]
Zhao S. [1 ]
Zheng L. [1 ]
Wang Z. [1 ]
Dong L. [2 ]
机构
[1] Key Laboratory of Distributed Energy Storage and Microgrid of Hebei Province, North China Electric Power University, Baoding
[2] State Grid Qinghai Electric Power Company, Xining
关键词
Damping ratio sensitivity; Electric power systems; Perturbation method; Photovoltaic access mode; Small disturbance stability; Stochastic response surface method;
D O I
10.16081/j.epae.202104020
中图分类号
学科分类号
摘要
Aiming at the impact of photovoltaic integration on system small disturbance stability, a solving method of damping ratio sensitivity based on random response surface method and perturbation method is proposed. The random excitation of photovoltaic output fluctuation is taken as the perturbation, and the damping ratio sensitivities are solved with photovoltaic accessed to grid on different nodes by the perturbation method. The optimum photovoltaic accessed node is selected according to the damping ratio sensitivity, the access location and capacity of photovoltaic power generation are determined through optimization method, and the optimum access mode of photovoltaic power generation is obtained. New England 10-generator 39-bus system and an actual power system in a western province are taken for examples, which verifies the effectiveness of the proposed method. © 2021, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:70 / 75
页数:5
相关论文
共 14 条
  • [1] HAN Dong, MA Jin, HE Renmu, Et al., Uncertainty analysis based on stochastic response surface method in power system simulation, Automation of Electric Power Systems, 35, 24, pp. 12-16, (2011)
  • [2] PAN Xiong, LIU Wenxia, XU Yuqin, Et al., Transient stability analysis of power system integrated with wind farm groups based on SRSM and Nataf method, Proceedings of the CSEE, 33, 16, pp. 56-62, (2013)
  • [3] MA Rui, QIN Jiaqian, Probabilistic continuous hybrid flow me-thod for electricity-gas coupling system integrated with DFIG wind farm and its load margin analysis, Electric Power Automation Equipment, 39, 8, pp. 38-46, (2019)
  • [4] MA Yanfeng, LIU Jia, YAN Jiyuan, Small disturbance stability analysis of power system containing wind power based on stochastic response surface method, Transactions of China Electrotechnical Society, 32, 6, pp. 49-57, (2017)
  • [5] ZHOU Yichen, Small signal stability analysis and control for power systems with large-scale concentrated solar photovoltaic plant, (2018)
  • [6] MA Jin, XU Hao, ZHANG Guofei, Et al., An eigenvalue sensitivity-based method to analyze effects of load model on system damping, Power System Technology, 35, 7, pp. 87-90, (2011)
  • [7] LIAO Qingfen, LIU Dichen, DANG Jie, Et al., Sensitivity analysis of low frequency oscillation eigenvalue to excitation system model and parameter, Electric Power Automation Equipment, 29, 3, pp. 69-73, (2009)
  • [8] MA Yanfeng, DU Jianglong, ZHAO Shuqiang, Hybrid areal oscillation control strategy of AC-DC power system, Electric Power Automation Equipment, 34, 8, pp. 52-57, (2014)
  • [9] LI Shenghu, JIANG Yitian, YU Xinyu, Et al., Small-signal stabi-lity constrained optimal power flow model considering optimization of DFIG pitch angle, Electric Power Automation Equipment, 39, 11, pp. 20-26, (2019)
  • [10] MENDOZA-ARMENTA S, DOBSON I., Applying a formula for generator redispatch to damp interarea oscillations using syn-chrophasors[J], IEEE Transactions on Power Systems, 31, 4, pp. 3119-3128, (2016)