Control strategy of ISOP battery test power supply based on DAB

被引:0
|
作者
Shi Y. [1 ]
Zhang Z. [1 ]
Chen Z. [2 ]
Peng K. [3 ]
机构
[1] Photovoltaic System Research and Engineering Center of the Ministry of Education, Hefei University of Technology, Hefei
[2] Institute of Electric Power Science of State Grid Anhui Electric Power Co., Ltd., Hefei
[3] Hefei Kewell Power System Co., Ltd., Hefei
关键词
battery testing; control strategy; converter with dual active bridge input in parallel and output in parallel; input-voltage sharing; output-current sharing; test power supply;
D O I
10.15938/j.emc.2022.08.009
中图分类号
学科分类号
摘要
Aiming at the problems of slow charging and discharging test speed and high energy consumption that traditional test power supply mostly adopts unidirectional energy consumption structure, a dual active bridge (DAB) is proposed as the basic module of input-series-output-parallel (ISOP) converter constitutes a test power supply, and at different stages of charging, the constant-current control and droop-voltage-limiting control strategy of ISOP-DAB converter are proposed. The proposed test power supply can improve the charging and discharging speed and reduce the energy consumption, and at the same time avoid the problem of large size and mass of the test device caused by the use of power frequency transformers. The working principle and modeling method of the ISOP-DAB converter in the test power supply were studied, and the equivalent model of the small-signal circuit was obtained. Compared with the input-voltage-sharing control strategies of ISOP-DAB converter, the modular control was selected for further research to realize the multi-module input-voltage sharing and output-current sharing while taking into account the realization of the segmented charging method. Finally, the effectiveness of the proposed method was verified by simulated experiments. © 2022 Editorial Department of Electric Machines and Control. All rights reserved.
引用
收藏
页码:79 / 87
页数:8
相关论文
共 14 条
  • [1] MENG Yanjing, BAI Chong, WANG Sue, Design of a battery charge and discharge efficiency test system [J], Journal of Shaanxi University of Science & Technology (Natural Science Edition), 34, 1, (2016)
  • [2] MA Shaohua, TAO Meng, Research on accelerated life test of lead-acid battery, Chinese LABAT Man, 50, 6, (2013)
  • [3] CHENG C, LAU R W, RATHI N K, Et al., Extraction of intrinsic parameters of lead-acid batteries using energy recycling technique, IEEE Transactions on Power Electronics, 34, 5, (2019)
  • [4] SHI J, LUO J, HE X., Common-duty-ratio control of input-series output-parallel connected phase-shift full-bridge DC-DC converter modules [J], IEEE Transactions on Power Electronics, 26, 11, (2011)
  • [5] LIU F, ZHOU G, RUAN X, Et al., An input-series-output-parallel converter system exhibiting natural input-voltage sharing and output-current sharing [J], IEEE Transactions on Industrial Electronics, 68, 2, (2021)
  • [6] ZUMEL P, ORTEGA L, LAZARO A, Et al., Control strategy for modular dual active bridge input series output parallel [C], 2013 IEEE 14 th Workshop on Control and Modeling for Power Electronics (COMPEL), pp. 1-7, (2013)
  • [7] DENG F, ZHANG X, LI X, Et al., Decoupling control strategy for input-series output-parallel systems based on dual active bridge DC-DC converters [C], 2018 9th IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG), pp. 1-8, (2018)
  • [8] QU L, ZHANG D, ZHANG B., Input voltage sharing control scheme for input series and output parallel connected DC-DC converters based on peak current control, IEEE Transactions on Industrial Electronics, 66, 1, (2019)
  • [9] XU G, SHA D, LIAO X., Decentralized inverse-droop control for input-series-output-parallel DC-DC converters, IEEE Transactions on Power Electronics, 30, 9, (2015)
  • [10] LIU Ran, LI Kunpeng, XU Lie, Et al., A parameter optimization method of dual active bridge converter considering the worst con-ditions, Electric Machines and Control, 23, 10, (2019)