On-chip ionic current sensor

被引:0
|
作者
Cheng, Chaojun [1 ]
Foxworthy, Grace [3 ]
Fridman, Gene [2 ,3 ,4 ]
机构
[1] Mechanical Engineering, Johns Hopkins University, Baltimore, United States
[2] Otolaryngology HNS, Johns Hopkins University, Baltimore, United States
[3] Biomedical Engineering, Johns Hopkins University, Baltimore, United States
[4] Computer and Electrical Engineering, Johns Hopkins University, Baltimore, United States
来源
Applied Physics A: Materials Science and Processing | 2021年 / 127卷 / 05期
基金
美国国家卫生研究院;
关键词
Controlled drug delivery - Charged particles - Microfluidics - Diagnosis - Electric fields - Targeted drug delivery - Disease control;
D O I
暂无
中图分类号
学科分类号
摘要
Neural implants that deliver drugs or electrical stimuli via microfluidic ports are promising in providing therapy for various disorders such as epilepsy, chronic pain, and vestibular diseases. To deliver the stimuli to a neural target, these devices incorporate two or more electrodes that apply an electric field to drive charged particles or ions along an aqueous route provided by microfluidic channels. The amount of drug/current delivered is determined by measuring the ionic current flow. When the ionic current can only travel from one electrode to another via a single route or channel, the amount of therapeutic current is stoichiometrically equal to the electronic current applied by the device and therefore can be measured with an electronic current sensor. However, some recently developed devices contain networks of branched channels. In this case, the presence of multiple parallel ionic current paths makes it so that the current through any one individual channel is no longer measurable by observing electronic current alone. Here, we present an on-chip sensor that uses two Pt/Ir electrodes to transduce the ionic current through a target channel into a measurable voltage signal. The size of the metal wires did not impact the measured voltage, the size of the channel between the two sensing electrodes determines sensitivity of the sensor, change in temperature can cause a change in readings, and input impedance of the voltage measuring equipment must be greater than 1 GΩ to maintain measurement stability. The sensor showed stability of reading in a one-week longevity test. © 2021, The Author(s), under exclusive licence to Springer-Verlag GmbH, DE part of Springer Nature.
引用
收藏
相关论文
共 50 条
  • [1] On-chip ionic current sensor
    Chaojun Cheng
    Grace Foxworthy
    Gene Fridman
    Applied Physics A, 2021, 127
  • [2] On-chip ionic current sensor
    Cheng, Chaojun
    Foxworthy, Grace
    Fridman, Gene
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2021, 127 (05):
  • [3] An on-chip IDDT current sensor based on current-to-voltage conversion
    Gyepes, Gabor
    Arbet, Daniel
    Majer, Libor
    Stopjakova, Viera
    2012 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS, 2012, : 87 - 90
  • [4] High speed, high bandwidth on-chip current and voltage sensor
    Kruppa, J.
    Hesidenz, D.
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 1337 - +
  • [5] On-chip eddy current sensor for proximity sensing and crack detection
    Sadler, D.J.
    Ahn, C.H.
    Sensors and Actuators, A: Physical, 2001, 90 (03) : 340 - 345
  • [6] Multi-site On-chip Current Sensor for Electromigration Monitoring
    Wang, Tianhan
    Chen, Degang
    Geiger, Randall
    2011 IEEE 54TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2011,
  • [7] On-chip eddy current sensor for proximity sensing and crack detection
    Sadler, DJ
    Ahn, CH
    SENSORS AND ACTUATORS A-PHYSICAL, 2001, 91 (03) : 340 - 345
  • [8] An On-chip High-voltage Current Sensor for Battery Module Monitoring
    Wang, Chua-Chin
    Lu, Wen-Je
    Wang, Sheng-Syong
    2014 IEEE INTERNATIONAL CONFERENCE ON IC DESIGN & TECHNOLOGY (ICICDT), 2014,
  • [9] A current sensor for on-chip, non-intrusive testing of RF systems
    Soldo, A
    Gopalan, A
    Mukund, PR
    Margala, M
    17TH INTERNATIONAL CONFERENCE ON VLSI DESIGN, PROCEEDINGS: DESIGN METHODOLOGIES FOR THE GIGASCALE ERA, 2004, : 1023 - 1026
  • [10] SRAM test using on-chip dynamic power supply current sensor
    Liu, J
    Makki, RZ
    1998 INTERNATIONAL WORKSHOP ON MEMORY TECHNOLOGY, DESIGN AND TESTING - PROCEEDINGS, 1998, : 57 - 63