Structural design and key technology of China International Silk Road Center super high-rise building

被引:0
|
作者
Ding J. [1 ,2 ]
Yu Z. [1 ]
Wu H. [1 ]
Wang J. [1 ]
Liu B. [1 ]
机构
[1] Architectural Design and Research Institute of Tongji University (Group) Co., Ltd., Shanghai
[2] College of Civil Engineering, Tongji University, Shanghai
关键词
FEA; Hybrid outrigger truss technique; Rigid outrigger truss; Seismic performance; Super high-rise building; Viscous damping outrigger truss;
D O I
10.14006/j.jzjgxb.2020.C177
中图分类号
学科分类号
摘要
The height of the super high-rise building-China International Silk Road Center is 498 m. The building is located in Xi'an Shaanxi province, where the seismic intensity is 8 degree, and the lateral deformation and load bearing capacity of the structure are both controlled by the seismic load. In order to solve the problem of insufficient lateral stiffness of the structure, the use of an outrigger truss strengthened storey was considered. However, the traditional outrigger truss often leads to an abrupt change in the stiffness and bearing capacity of the structure. To address this issue, the hybrid outrigger technology involving both rigid and viscous damping outriggers was applied to the building design. The optimum position and efficiency of the outrigger truss arrangement were investigated through calculation and analysis, taking into consideration the structural index, structural energy dissipation, member stress and economic aspects. The layout of viscous damping outrigger truss in the upper two refuge areas and the rigid outrigger truss in the lower two refuge areas was proposed. From the aspects of structural response and structural damage, the seismic performance of the structure under different levels of earthquake was analyzed, and the finite element analysis of the key joints of the outrigger truss was carried out. The results show that, by using the hybrid outrigger truss technique, the energy dissipation mechanism of the structure can be improved, the seismic response and member damage can be reduced, and the outrigger truss is safe and reliable. © 2021, Editorial Office of Journal of Building Structures. All right reserved.
引用
收藏
页码:1 / 14
页数:13
相关论文
共 15 条
  • [1] JIANG Wenhui, CHAO Si, Variable rigidity design in the pile foundation of Shanghai Tower, Journal of Building Structures, 42, 6, pp. 132-134, (2012)
  • [2] DING Jiemin, WU Honglei, ZHAO Xin, Current situation and discussion of structural design for super high-rise buildings above 250m in China, Journal of Building Structures, 35, 3, pp. 1-7, (2014)
  • [3] WU Honglei, DING Jiemin, CUI Jianqiao, Et al., Study on energy dissipation technology and connection design for outriggers and belt members of super high-rise buildings, Journal of Building Structures, 35, 3, pp. 8-15, (2014)
  • [4] DING Jiemin, WANG Shiyu, WU Honglei, Application research of viscous damping outriggertruss in super high-rise building, Journal of Building Structures, 37, pp. 48-54, (2016)
  • [5] DING Jiemin, WU Honglei, Design guidelines and engineering applications of building structure adopting seismic mitigation and isolation technology, pp. 27-48, (2018)
  • [6] CHEN Yongqi, CAO Tiezhu, Vibration reduction of fluid viscous dampers on Beijing high-rise building in Pangu Plaza, Steel Construction, 24, 8, pp. 39-46, (2009)
  • [7] CHEN Yongqi, GAO Zheng, BO Yang, Seismic damper for the Torre Mayor high rise building at Mexico City, Steel Construction, 26, 1, pp. 50-54, (2011)
  • [8] SMITH R J, WILLFORD M R., The damped outrigger concept for tall buildings, The Structural Design of Tall and Special Buildings, 16, 4, pp. 501-517, (2007)
  • [9] Technical specification for concrete structures of tall buildings: JGJ 3-2010, (2010)
  • [10] WU Honglei, DING Jiemin, LIU Bo, Application research of viscous damping outrigger truss in super high-rise building, Journal of Building Structures, 41, 3, pp. 14-24, (2020)