Exploring a Multizone To Variable Volume HVAC Controls Retrofit

被引:0
|
作者
Westervelt, Eileen T.
Bush, Joseph
Schwenk, David M.
机构
关键词
Cooling; -; Retrofitting;
D O I
暂无
中图分类号
学科分类号
摘要
The U.S. Department of Defense (DOD) has thousands of 10 to 40+ year old multizone air-handling units (AHUs) in operation. These constant volume, variable temperature units are quick to meet space temperature needs, but they can be very energy inefficient. Multizone units deliver a constant volume of air to the building zones serviced, regardless of the actual cooling, heating and ventilation requirements of each zone. Further, the conventional two-deck multizone uses continuous, simultaneous operation of the heating and cooling coils, even when additional heating or cooling is not needed. Modern alternative system replacements (such as variable air volume systems) help address these inefficiencies but are costly and disruptive to install. This article presents an energy savings retrofit of the multizone control system that provides variable volume airflow at significantly lower expense and with less disturbance than a complete system change out. © 2022 Amer. Soc. Heating, Ref. Air-Conditoning Eng. Inc.. All rights reserved.
引用
收藏
页码:32 / 47
相关论文
共 50 条
  • [1] Exploring a Multizone To Variable Volume HVAC Controls Retrofit
    Westervelt, Eileen T.
    Bush, Joseph
    Schwenk, David M.
    ASHRAE JOURNAL, 2022, 64
  • [2] SIMULATION OF PERFORMANCE OF MULTIZONE AND VARIABLE VOLUME HVAC SYSTEMS IN 4 GEOGRAPHIC LOCATIONS
    HITTLE, DC
    HERRON, DL
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1976, 18 (12): : 46 - 46
  • [3] HVAC and controls retrofit of a manufacturing plant
    Gill, KE
    Patterson, JH
    BUILDING FOR THE 21ST CENTURY: ENERGY & THE ENVIRONMENT, 2000, : 187 - 192
  • [4] Multizone Air Handler Controls Retrofit for Energy Efficiency
    Westervelt, Eileen T.
    Battisti, Christopher M.
    Morton, Brianna K.
    Schwenk, David M.
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 1, 2021, 127 : 73 - 80
  • [5] HVAC and controls retrofit of a manufacturing plant: Part I
    Aguirre Corp, Dallas, United States
    HPAC Heat Piping Air Cond, 11
  • [6] Bilinear model-based diagnosis of lock-in-place failures of variable-air-volume HVAC systems of multizone buildings
    Subramaniam, Mona
    Jain, Tushar
    Yame, Joseph J.
    JOURNAL OF BUILDING ENGINEERING, 2020, 28
  • [7] HVAC retrofit for campus
    King, JE
    ASHRAE JOURNAL, 2001, 43 (06) : 67 - 68
  • [8] Holistic HVAC Retrofit
    Talend, Don
    MECHANICAL ENGINEERING, 2009, 131 (08) : 22 - 22
  • [9] Dynamic behavior of variable water volume HVAC system
    Chen, Zhenqian
    Wang, Jing
    Shi, Mingheng
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 57 - 60
  • [10] REDUCING ENERGY COSTS WITH VARIABLE AIR VOLUME HVAC SYSTEMS
    SCHMIDT, RD
    PLANT ENGINEERING, 1977, 31 (06) : 143 - 144