On-site transient performance calibration of DC current transformer for HVDC transmission project

被引:0
|
作者
Pang F. [1 ]
Liu Y. [1 ]
Ji J. [1 ]
Bu Q. [1 ]
Zhang C. [1 ]
机构
[1] State Grid Jiangsu Electric Power Co., Ltd. Research Institute, Nanjing
基金
中国国家自然科学基金;
关键词
DC current transformer; On-site calibration; Pre-distorting adjustment; Signal resampling; Transient performance;
D O I
10.19783/j.cnki.pspc.180947
中图分类号
学科分类号
摘要
With the constantly development of High-Voltage Direct Current (HVDC) transmission system construction, the on-site calibration of DC current transformer has become the major research interest in HVDC transmission field. According to the research gap of the on-site transient performance calibration technology, the working principle of the existing DC current transformer and the on-site calibration method are analyzed. A set of portable transient performance calibration system for DC current transformer is devised based on signal resampling and pre-distorting adjustment. By revision, the system produces the large step current close to the simulation signal, and its 500 kHz high speed sending and collecting modules ensure the accuracy of the sampling and waveform restoring during the transient process. Furthermore, the first on-site transient performance test of the pole and converter valve DC current transformers has been carried out with the system in Sunan UPFC Project. The rising time, maximum overshoot and the transient delay of the pole and converter valve transformers are tested, and the results provide the basis for the evaluation of the DC current transformers. The technology has a good application prospect for the on-site DC current transformer calibration. © 2019, Power System Protection and Control Press. All right reserved.
引用
收藏
页码:179 / 187
页数:8
相关论文
共 25 条
  • [1] Liang X., Zhang P., Chang Y., Recent advances in high-voltage direct-current power transmission and its developing potential, Power System Technology, 36, 4, pp. 1-9, (2012)
  • [2] Xu P., Huang J., Xu J., Et al., Study of Bin-Jin UHVDC project commutation failures protection, Power System Protection and Control, 45, 2, pp. 140-146, (2017)
  • [3] Liu K., Zhang Q., Shi Q., Application of coordinated frequency control function in Lingshao ±800 kV UHVDC project, Electric Power Engineering Technology, 37, 4, pp. 14-20, (2018)
  • [4] Zhang J., Hu Y., Liu F., Et al., Critical technology of on-site calibration system for DC electronic instrument transformer, High Voltage Engineering, 42, 9, pp. 3003-3010, (2016)
  • [5] Yang Y., Tai N., Fan C., Et al., A pilot protection scheme for HVDC transmission lines based on calculated resistance, Transactions of China Electrotechnical Society, 32, 7, pp. 84-94, (2017)
  • [6] Chen B., Li J., Wang J., Et al., Technology and its application of high precision optical voltage transformer, Power System and Clean Energy, 33, 6, pp. 7-13, (2017)
  • [7] Xi C., Cheng J., Yang S., The application of optical current transformer in converter station DC filter and its fault reason analysis, Power System Technology, 32, 1, pp. 17-19, (2008)
  • [8] Bu Q., Wang J., Yuan Y., Et al., Research and application of the polarity verification system of electronic transformers, Jiangsu Electrical Engineering, 31, 5, pp. 32-36, (2012)
  • [9] Li Q., Li H., Zhou Y., Et al., On-site calibration technology of DC current measurement device in converter station of ±800 kV UHVDC transmission project, High Voltage Engineering, 37, 12, pp. 3053-3058, (2011)
  • [10] Bai H., Xu Y., Xiao X., Et al., Research on field calibration methods and key problems for HVDC electronic current transformers, Proceedings of the CSEE, 36, 19, pp. 5227-5236, (2016)